FDC37B78X SMSC Corporation, FDC37B78X Datasheet - Page 41

no-image

FDC37B78X

Manufacturer Part Number
FDC37B78X
Description
Enhanced Super I/O Controller with ACPI Support/ Real Time Clock and Consumer IR
Manufacturer
SMSC Corporation
Datasheet
Commands can be written whenever the FDC is
in the command phase. Each command has a
unique set of needed parameters and status
results. The FDC checks to see that the first
byte is a valid command and, if valid, proceeds
with the command. If it is invalid, an interrupt is
issued.
C
D
D0, D1
DIR
DS0, DS1
DTL
EC
EFIFO
EIS
EOT
GAP
GPL
SYMBOL
The user sends a Sense Interrupt
Cylinder Address
Data Pattern
Drive Select 0-1
Direction Control
Disk Drive Select
Special Sector
Size
Enable Count
Enable FIFO
Enable Implied
Seek
End of Track
Gap Length
NAME
TABLE 20 - DESCRIPTION OF COMMAND SYMBOLS
COMMAND SET/DESCRIPTIONS
The currently selected address; 0 to 255.
The pattern to be written in each sector data field during
formatting.
Designates which drives are perpendicular drives on the
Perpendicular Mode Command. A "1" indicates a perpendicular
drive.
If this bit is 0, then the head will step out from the spindle during a
relative seek. If set to a 1, the head will step in toward the spindle.
DS1 DS0 Drive Selected
By setting N to zero (00), DTL may be used to control the number
of bytes transferred in disk read/write commands. The sector size
(N = 0) is set to 128. If the actual sector (on the diskette) is larger
than DTL, the remainder of the actual sector is read but is not
passed to the host during read commands; during write
commands, the remainder of the actual sector is written with all
zero bytes. The CRC check code is calculated with the actual
sector. When N is not zero, DTL has no meaning and should be
set to FF HEX.
When this bit is "1" the "DTL" parameter of the Verify command
becomes SC (number of sectors per track).
This active low bit when a 0, enables the FIFO. A "1" disables the
FIFO (default).
When set, a seek operation will be performed before executing any
read or write command that requires the C parameter in the
command phase. A "0" disables the implied seek.
The final sector number of the current track.
Alters Gap 2 length when using Perpendicular Mode.
The Gap 3 size. (Gap 3 is the space between sectors excluding
the VCO synchronization field).
0
0
0
1
Drive 0
Drive 1
41
Status command which returns an invalid
command error.
explanations of the various symbols used.
TABLE 21 lists the required parameters and the
results associated with each command that the
FDC is capable of performing.
DESCRIPTION
Refer to TABLE 20 for

Related parts for FDC37B78X