AIP
PORT
AIA
ADDR
RREGSEL
Receive T1/E1 Framer Port & Register Select
Access
Address
Reset Value
Note: This register is an indirect access register, which must be programmed before
Data Sheet
15
0
accessing the register RDATA.
AIP
14
0
: read/write
: 118
: 0000
Auto Increment Port
This bit enables the auto increment function of bit field PORT. Each read/
write access to register RDATA increments PORT. This allows to
program multiple, consecutive ports without accessing RREGSEL again.
0
1
Port Select
This bit field selects the port number, which can be accessed via register
RDATA.
0..27 Port Number.
Auto Increment Address
This bit enables the auto increment function of bit field ADDR. Each
read/write access to register RDATA increments ADDR. This allows to
program multiple, consecutive registers without accessing RREGSEL
again.
0
1
Register Address
This bit field selects the register address of the transmit framer, which
can be accessed via register RDATA.
0
H
..7F
12
H
H
H
(PCI), 0C
Disable auto increment function.
Enable auto increment function.
Disable auto increment function.
Enable auto increment function.
Register address.
PORT(4:0)
H
(Local Bus)
8
254
AIA
7
6
ADDR(6:0)
Register Description