ATtiny26 Atmel Corporation, ATtiny26 Datasheet - Page 35

no-image

ATtiny26

Manufacturer Part Number
ATtiny26
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATtiny26

Flash (kbytes)
2 Kbytes
Pin Count
20
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
Hardware Qtouch Acquisition
No
Max I/o Pins
16
Ext Interrupts
11
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
11
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
0.12
Eeprom (bytes)
128
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
3
Pwm Channels
4
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATTINY26
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATtiny26-16MI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATtiny26-16MU
Manufacturer:
ATMEL
Quantity:
7 119
Part Number:
ATtiny26-16SC
Manufacturer:
MITEL
Quantity:
20 000
Part Number:
ATtiny26-16SI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATtiny26-16SU
Manufacturer:
ATMEL
Quantity:
8 000
Part Number:
ATtiny26-16SU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATtiny26-8PI
Manufacturer:
UTC
Quantity:
15
Part Number:
ATtiny26-8SI
Manufacturer:
INTEL
Quantity:
8
Part Number:
ATtiny26-8SU
Manufacturer:
ATMTLL
Quantity:
5 510
Part Number:
ATtiny26-8SU
Manufacturer:
SIEMENS
Quantity:
5 510
Brown-out
Detection
Watchdog Reset
1477K–AVR–08/10
ATtiny26(L) has an On-chip Brown-out Detection (BOD) circuit for monitoring the V
ing the operation. The BOD circuit can be enabled/disabled by the fuse BODEN. When the BOD
is enabled (BODEN programmed), and V
Reset is immediately activated. When V
Reset is deactivated after a delay. The delay is defined by the user in the same way as the delay
of POR signal, in Table 29. The trigger level for the BOD can be selected by the fuse
BODLEVEL to be 2.7V (BODLEVEL unprogrammed), or 4.0V (BODLEVEL programmed). The
trigger level has a hysteresis of 50 mV to ensure spike free Brown-out Detection.
The BOD circuit will only detect a drop in V
ger than t
Figure 29. Brown-out Reset During Operation
When the Watchdog times out, it will generate a short reset pulse of one CK cycle duration. On
the falling edge of this pulse, the delay timer starts counting the Time-out period t
page 78 for details on operation of the Watchdog.
Figure 30. Watchdog Time-out
INTERNAL
TIME-OUT
RESET
RESET
BOD
V
CC
given in Table 16.
V
BOT-
1 CK Cycle
CC
CC
CC
increases above the trigger level, the Brown-out
decreases below the trigger level, the Brown-out
if the voltage stays below the trigger level for lon-
V
t
TOUT
BOT+
TOUT
CC
. Refer to
level dur-
35

Related parts for ATtiny26