COM20022I3V-HT SMSC, COM20022I3V-HT Datasheet - Page 54

IC CTRLR ARCNET 2KX8 RAM 48-TQFP

COM20022I3V-HT

Manufacturer Part Number
COM20022I3V-HT
Description
IC CTRLR ARCNET 2KX8 RAM 48-TQFP
Manufacturer
SMSC
Series
ARCNETr
Datasheet

Specifications of COM20022I3V-HT

Controller Type
ARCNET Controller
Interface
Differential
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
65mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-TQFP, 48-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
638-1004

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
COM20022I3V-HT
Manufacturer:
Standard
Quantity:
2 784
Part Number:
COM20022I3V-HT
Manufacturer:
AD
Quantity:
7 439
Part Number:
COM20022I3V-HT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
COM20022I3V-HT
Manufacturer:
SMSC
Quantity:
20 000
Part Number:
COM20022I3V-HT
0
6.10
6.10.1 Normal Results:
Revision 09-27-07
The user may then attempt a new ID value, wait 210mS before checking the Duplicate ID bit, and repeat
the process until a unique Node ID is found. At this point, the TX Enable bit may be set to allow the node
to join the network. Once the node joins the network, a reconfiguration occurs, as usual, thus setting the
MYRECON bit of the Diagnostic Status Register.
The Tentative ID Register may be used to build a network map of all the nodes on the network, even once
the COM20022I has joined the network.
COM20022I looks for a response to a token whose DID matches the Tentative ID Register. The software
can record this information and continue placing Tentative ID values into the register to continue building
the network map. A complete network map is only valid until nodes are added to or deleted from the
network. Note that a node cannot detect the existence of the next logical node on the network when using
the Tentative ID. To determine the next logical node, the software should read the Next ID Register.
Improved Diagnostics
The COM20022I allows the user to better manage the operation of the network through the use of the
internal Diagnostic Status Register.
A high level on the My Reconfiguration (MYRECON) bit indicates that the Token Reception Timer of this
node expired, causing a reconfiguration by this node. After the Reconfiguration (RECON) bit of the Status
Register interrupts the microcontroller, the interrupt service routine will typically read the MYRECON bit of
the Diagnostic Status Register.
Successive occurrences of a logic "1" on the MYRECON bit indicates that a problem exists with this node.
At that point, the transmitter should be disabled so that the entire network is not held down while the node
is being evaluated.
The Duplicate ID (DUPID) bit is used before the node joins the network to ensure that another node with
the same ID does not exist on the network. Once it is determined that the ID in the Node ID Register is
unique, the software should write a logic "1" to bit 5 of the Configuration Register to enable the basic
transmit function. This allows the node to join the network.
The Receive Activity (RCVACT) bit of the Diagnostic Status Register will be set to a logic "1" whenever
activity (logic "1") is detected on the RXIN pin.
The Token Seen (TOKEN) bit is set to a logic "1" whenever any token has been seen on the network
(except those tokens transmitted by this node).
The RCVACT and TOKEN bits may help the user to troubleshoot the network or the node. If unusual
events are occurring on the network, the user may find it valuable to use the TXEN bit of the Configuration
Register to qualify events. Different combinations of the RCVACT, TOKEN, and TXEN bits, as shown
indicate different situations:
RCVACT=1, TOKEN=1, TXEN=0: The node is not part of the network. The network is operating properly
without this node.
RCVACT=1, TOKEN=1, TXEN=1: The node sees receive activity and sees the token. The basic transmit
function is enabled. Network and node are operating properly.
MYRECON=0, DUPID=0, RCVACT=1, TXEN=0, TOKEN=1: Single node network.
DATASHEET
Reading the Diagnostic Status Register resets the MYRECON bit.
Page 54
Once a value is placed in the Tentative ID Register, the
10 Mbps ARCNET (ANSI 878.1) Controller with 2Kx8 On-Chip RAM
SMSC COM20022I
Datasheet