2.2.8
The IOM-2 interface can be switched off in the inactive state, reducing power
consumption to a minimum. In this deactivated state is FSC = ’1’, DCL = ’0’ and BCL =
’1’ and the data lines are ’1’. The data between the functional blocks of the SCOUT-DX
is then transferred internally.
The IOM-2 interface can be kept active while the line interface is deactivated by setting
the CFS bit to "0" (MODE register). This is the case after a hardware reset. If the IOM-2
interface should be switched off while the line interface is deactivated, the CFS bit should
be set to ’1’. In this case the internal oscillator is disabled when no signal (info 0) is
present on the line interface and the C/I command is ’1111’ = DIU (refer to chapter
2.3.4.1.3 and 2.3.4.1.6). If the TE wants to activate the line, it has first to activate the
IOM-2 interface either by using the "Software Power Up" function (IOM_CR.SPU bit) or
by setting the CFS bit to "0" again.
The deactivation procedure is shown in figure 31. After detecting the code DIU
(Deactivate Indication Upstream) the layer 1 of the SCOUT-DX responds by transmitting
DID (Deactivate Indication Downstream) during subsequent frames and stops the timing
signals synchronously with the end of the last C/I (C/I0) channel bit of the fourth frame.
Figure 31
Deactivation of the IOM
Data Sheet
IOM -2
FSC
DU
DD
DCL
R
Activation/Deactivation of IOM-2 Interface
DIU
DR
DIU
DR
®
-Interface
DIU
DR
DIU
DR
DIU
DR
B1
62
DIU
DID
D
B2
DIU
DID
MONO
CIO
DID
DIU
D
ITD09655
CIO
DIU
DID
IOM -2
Deactivated
PSB 21373
2002-05-13