PSB21373HV1.1XT Infineon Technologies, PSB21373HV1.1XT Datasheet - Page 47

no-image

PSB21373HV1.1XT

Manufacturer Part Number
PSB21373HV1.1XT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of PSB21373HV1.1XT

Lead Free Status / RoHS Status
Compliant
Data Sheet
2.2.4
The IOM-2 MONITOR channel (see figure 11) is utilized for information exchange
between the SCOUT-DX and other devices connected to the MONITOR channel.
The MONITOR channel data can be controlled by the bits in the MONITOR control
register (MON_CR). For the MONITOR data one of the three IOM channels can be
selected by setting the MONITOR channel selection bits (MCS). The DPS bit in the same
register selects between an output on DU or DD respectively and with EN_MON the
MONITOR data can be enabled/disabled. The default value is MONITOR channel 0
(MON0) enabled and transmission on DD.
Figure 22
Examples of MONITOR Channel Applications
Data Exchange between two Microcontroller Systems
e.g. ARCOFI-BA
V/D Module
V/D Module
PSB 2161
PSB 7238
e.g. Jade
µC
IOM-2 MONITOR Channel
IOM-2 MONITOR Channel
IOM-2 Monitor Channel
CODEC
CODEC
MONITOR Handler
MONITOR Handler
µC
µC
SCOUT as
Master Device
SCOUT as
Master Device
Layer 1
Layer 1
SCOUT
SCOUT
47
V/D Module
PSB 7238
e.g. Jade
µC
IOM-2 MONITOR Channel
CODEC
MONITOR Handler
SCOUT as
Slave Device
PSB 21373
Layer 1
2002-05-13
SCOUT
monappl

Related parts for PSB21373HV1.1XT