CS1D-II102D Omron, CS1D-II102D Datasheet - Page 559

no-image

CS1D-II102D

Manufacturer Part Number
CS1D-II102D
Description
CS1D Dual IO Interface Unit
Manufacturer
Omron
Datasheet

Specifications of CS1D-II102D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
524
Auxiliary Area Allocations
A344
A346
and
A347
A351 to
A354
Words
Address
All
All
All
A35100
to
A35107
A35108
to
A35115
A35200
to
A35207
A35208
to
A35215
A35300
to
A35307
A35308
to
A35315
A35400
to
A35407
Bits
EM File
Memory
Starting
Bank
Number of
Remain-
ing Words
to Transfer
Calendar/
Clock Area
Name
Contains the starting bank number
of EM file memory (bank number of
the first formatted bank). All EM
banks from this starting bank to the
last bank in EM are formatted for
use as file memory.
To convert the EM Area for use as
file memory, first set the PLC
Setup’s EM File Memory Function
setting to 1, set the PLC Setup’s EM
File Memory Starting Bank setting (0
to C), and then format the EM Area
from a Programming Device
The PLC Setup’s EM file memory
settings won’t agree with the actual
settings unless the EM Area is for-
matted after the PLC Setup’s EM file
memory settings have been
changed. In that case, the actual
settings can be determined with this
word.
These words contain the 8-digit
hexadecimal number of words
remaining to be transferred by
FREAD(700) or FWRIT(701). When
one of these instructions is exe-
cuted, the number of words to be
transferred is written to A346 and
A347.
While the data is being transferred,
the value in these words is decre-
mented.
A326 contains the rightmost 4-digits
and A347 contains the leftmost 4-
digits.
Check the content of these words to
determine whether or not the
planned number of words have been
transferred successfully.
These words contain the CPU Unit’s
internal clock data in BCD. The clock
can be set from a Programming
Device such as a Programming
Console, with the DATE(735)
instruction, or with a FINS command
(CLOCK WRITE, 0702).
Seconds (00 to 59) (BCD)
Minutes (00 to 59) (BCD)
Hours (00 to 23) (BCD)
Day of the month (01 to 31) (BCD)
Month (01 to 12) (BCD)
Year (00 to 99) (BCD)
Day of the week (00 to 06) (BCD)
00: SUN, 01: MON, 02: TUE,
03: WED, 04: THU,05: FRI, 06: SAT
Function
0000 to 000C
hex
Bank 0 to C
Data remaining
in transfer
---
Settings
Held
Held
Held
change
Status
mode
after
Held
Cleared
Held
Status at
startup
When EM
file for-
matting is
performed
Written as
FREAD or
FWRIT is
being exe-
cuted.
Decre-
mented as
data is
actually
trans-
ferred.
Written
every
cycle
Timing
Appendix B
PLC
Setup
(EM File
Memory
Func-
tion set-
ting and
EM File
Memory
Starting
Bank
setting)
---
---
settings
Related
flags,

Related parts for CS1D-II102D