CS4525-CNZR Cirrus Logic Inc, CS4525-CNZR Datasheet - Page 93

IC PWM Controller+power Stage

CS4525-CNZR

Manufacturer Part Number
CS4525-CNZR
Description
IC PWM Controller+power Stage
Manufacturer
Cirrus Logic Inc
Series
Popguard®r
Type
Class Dr
Datasheet

Specifications of CS4525-CNZR

Output Type
2-Channel (Stereo) or 4-Channel (Quad)
Max Output Power X Channels @ Load
30W x 1 @ 4 Ohm; 15W x 2 @ 8 Ohm
Voltage - Supply
8 V ~ 18 V
Features
ADC, Depop, I²C, I²S, Mute, PWM, Short-Circuit and Thermal Protection, Volume Control
Mounting Type
Surface Mount
Package / Case
48-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1586 - REFERENCE BOARD FOR CS4525 PWM
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS4525-CNZR
Manufacturer:
CIRRUSLOGICINC
Quantity:
20 000
DS726PP3
9.21.4 Channel X Overflow (ChXOvflSt)
9.21.5 Ramp-Up Cycle Complete (RampDone)
9.22
All bits in this register are considered “level-triggered” events, meaning as long as a condition continues, the corre-
sponding bit will remain set. These status bits are not affected by the interrupt mask bit and the condition of each bit
can be polled. These bits will not be cleared following a read to this register, nor can they be written to cause an
interrupt condition.
9.22.1 Over-Current Detected On Channel X (OverCurrX)
9.22.2 External Amplifier State (ExtAmpSt)
OverCurr4
7
Amplifier Error Status (Address 62h) - Read Only
Function:
These bits are read only and will identify the presence of an overflow condition anywhere in the associated
channel’s signal path. When set, indicates that an over-range condition is currently occurring in the chan-
nel’s signal path and has been clipped to positive or negative full scale.
Function:
When set, indicates that all active channels have completed the configured ramp-up interval.
Function:
When set, indicates an over current condition is currently present on the corresponding amplifier output.
Function:
When set, indicates a thermal warning condition is currently being reported by an external amplifier. For
proper operation, the delay serial port must be configured to support an external thermal warning input
signal. This status bit reflects the active state of the external thermal warning input signal.
ChXOvflSt Setting
RampDone Setting
OverCurrX Setting
ExtAmpSt Setting
0 ..........................................An overflow condition is not currently present on channel X.
1 ..........................................An overflow condition is currently present on channel X.
0 ..........................................Ramp-up interval not completed on all channels.
1 ..........................................Ramp-up interval completed on all channels.
0 ..........................................An over current condition is not currently present on amplifier output X.
1 ..........................................An over current condition is currently present on amplifier output X.
0 ..........................................A thermal warning condition is not currently being reported by an external amplifier.
1 ..........................................A thermal warning condition is currently being reported by an external amplifier.
OverCurr3
6
OverCurr2
Channel X Overflow State
Ramp Completion State
Amplifier Over-Current Status
External Amplifier Status
5
OverCurr1
4
ExtAmpErr
3
Reserved
2
UVTE1
1
CS4525
UVTE0
0
93

Related parts for CS4525-CNZR