CV500BC101 Omron, CV500BC101 Datasheet - Page 171

no-image

CV500BC101

Manufacturer Part Number
CV500BC101
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500BC101

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
146
Setting Data Links
Example:
Example:
IR/CIO Area
DM Area
5. The following values must be satisfied to ensure that the data link area is
6. If a node that does not actually exist (e.g., a node that is scheduled to be
7. Automatic data link creation with 1:N allocation can only be performed with
8. If automatic data link creation with 1:N allocation is to be set up using CX-
9. The startup node (the node that sets the above DM parameter and starts
10. When data links are automatically created for networks containing
DM24575
fully contained within the specified area.
added in the future) is registered as a node that will participate in the data
links, a data link area for that node will be allocated in the master node, and
the send/receive area will be refreshed with “0” data.
CS1W-CLK21-V1,
3G8F7-CLK21-V1, and 3G8F7-CLK23-E Controller Link Units. If any other
model is used, the LNK LED will flash and it will not be possible to partici-
pate in the automatic creation with 1:N allocation.
Net operations in the CX-Programmer, use CX-Programmer Version 3.2 or
higher. Setup cannot be performed using CX-Programmer Version 3.2 or
lower.
the data link) can be set at either a master node or a slave node.
C200HX/HG/HE PLCs, CS/CJ-series PLCs, CVM1, CV-series, and
CQM1H-series PLCs, the linkable area is restricted to the area of the
CVM1, CV-series, C200HX/HG/HE, or CQM1H-series PLC because it is
smaller than that of CS/CJ-series PLCs.
DM000
C200HX/HG/HE or
CQM1H-series PLCs
to
235
Total number of words in data link send and receive areas of master
node =
Number of common send words in master node +
Number of individual send words in each node × Number of nodes par-
ticipating in data links (including both master nodes and slave nodes)
(Area start word − 1) + (Total number of send and receive words of
master node *)
≤ 6143 (when using the IR or CIO Area)
* Total number of send and receive words in master node =
Number of common send words in master node +
Number of delivery send words in master node × Number of nodes
participating in data links (including both master nodes and slave
nodes)
to
199 (when using LR Area)
32767 (when using DM or EM Area)
0
CVM1 or
CV-series PLCs
DM24575
DM32767
DM000
CS1W-CLK23,
6655
235
to
to
to
to
0
CS/CJ-series PLCs
CS/CJ-series PLCs
Available for the data links
Not available for the data links
Available for the data links
Not available for the data links
CJ1W-CLK21-V1,
Section 5-2
CJ1W-CLK23,

Related parts for CV500BC101