SI4031-B1-FM Silicon Laboratories Inc, SI4031-B1-FM Datasheet - Page 44

IC TX 240-930MHZ -8-13DB 20VQFN

SI4031-B1-FM

Manufacturer Part Number
SI4031-B1-FM
Description
IC TX 240-930MHZ -8-13DB 20VQFN
Manufacturer
Silicon Laboratories Inc
Type
ISM Transmitterr
Datasheet

Specifications of SI4031-B1-FM

Package / Case
20-VQFN
Frequency
240MHz ~ 930MHz
Applications
General Purpose
Modulation Or Protocol
FSK, GFSK, OOK
Data Rate - Maximum
256 kbps
Power - Output
13dBm
Current - Transmitting
30mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Voltage - Supply
1.8 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Operating Frequency
240 MHz to 930 MHz
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Operating Supply Voltage
1.8 V to 3.6 V
Supply Current
30 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI4031-B1-FM
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
SI4031-B1-FMR
Manufacturer:
INFINEON
Quantity:
12 000
Part Number:
SI4031-B1-FMR
0
Company:
Part Number:
SI4031-B1-FMR
Quantity:
10 000
Si4030/31/32-B1
7.5. Low Battery Detector
A low battery detector (LBD) with digital read-out is integrated into the chip. A digital threshold may be programmed
into the lbdt[4:0] field in "Register 1Ah. Low Battery Detector Threshold." When the digitized battery voltage
reaches this threshold an interrupt will be generated on the nIRQ pin to the microcontroller. The microcontroller can
confirm source of the interrupt by reading "Register 03h. Interrupt/Status 1" and “Register 04h. Interrupt/Status 2,”
on page 56.
If the LBD is enabled while the chip is in SLEEP mode, it will automatically enable the RC oscillator which will
periodically turn on the LBD circuit to measure the battery voltage. The battery voltage may also be read out
through "Register 1Bh. Battery Voltage Level" at any time when the LBD is enabled. The low battery detect function
is enabled by setting enlbd=1 in "Register 07h. Operating Mode and Function Control 1".
The LBD output is digitized by a 5-bit ADC. When the LBD function is enabled, enlbd = 1 in "Register 07h.
Operating Mode and Function Control 1", the battery voltage may be read at anytime by reading "Register 1Bh.
Battery Voltage Level." A battery voltage threshold may be programmed in “Register 1Ah. Low Battery Detector
Threshold." When the battery voltage level drops below the battery voltage threshold an interrupt will be generated
on the nIRQ pin to the microcontroller if the LBD interrupt is enabled in “Register 06h. Interrupt Enable 2,” on page
59. The microcontroller will then need to verify the interrupt by reading the interrupt status register, addresses 03
and 04h. The LSB step size for the LBD ADC is 50 mV, with the ADC range demonstrated in the table below. If the
LBD is enabled the LBD and ADC will automatically be enabled every 1 s for approximately 250 µs to measure the
voltage which minimizes the current consumption in Sensor mode. Before an interrupt is activated four consecutive
readings are required.
44
Ad R/W
1A
1B
R/W
R
Low Battery Detector Threshold
Function/Description
Battery Voltage Level
BatteryVol
ADC Value
29
30
31
0
1
2
D7
0
tage
D6
0
1
Rev 1.1
7 .
VDD Voltage [V]
50
D5
0
mV
1.7–1.75
1.75–1.8
3.1–3.15
3.15–3.2
< 1.7
> 3.2
vbat[4] vbat[3] vbat[2] vbat[1] vbat[0]
lbdt[4]
D4
ADCValue
lbdt[3]
D3
lbdt[2]
D2
lbdt[1]
D1
lbdt[0]
D0
POR Def.
14h