SI4031-B1-FM Silicon Laboratories Inc, SI4031-B1-FM Datasheet - Page 38

IC TX 240-930MHZ -8-13DB 20VQFN

SI4031-B1-FM

Manufacturer Part Number
SI4031-B1-FM
Description
IC TX 240-930MHZ -8-13DB 20VQFN
Manufacturer
Silicon Laboratories Inc
Type
ISM Transmitterr
Datasheet

Specifications of SI4031-B1-FM

Package / Case
20-VQFN
Frequency
240MHz ~ 930MHz
Applications
General Purpose
Modulation Or Protocol
FSK, GFSK, OOK
Data Rate - Maximum
256 kbps
Power - Output
13dBm
Current - Transmitting
30mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Voltage - Supply
1.8 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Operating Frequency
240 MHz to 930 MHz
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Operating Supply Voltage
1.8 V to 3.6 V
Supply Current
30 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI4031-B1-FM
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
SI4031-B1-FMR
Manufacturer:
INFINEON
Quantity:
12 000
Part Number:
SI4031-B1-FMR
0
Company:
Part Number:
SI4031-B1-FMR
Quantity:
10 000
Si4030/31/32-B1
6.6. TX Retransmission and Auto TX
The Si4030/31/32 is capable of automatically retransmitting the last packet loaded in the TX FIFO. Automatic
retransmission is set by entering the TX state with the txon bit without reloading the TX FIFO. This feature is useful
for beacon transmission or when retransmission is required due to the absence of a valid acknowledgement. Only
packets that fit completely in the TX FIFO can be automatically retransmitted.
An automatic transmission function is available, allowing the radio to automatically start or stop a transmission
depending on the amount of data in the TX FIFO.
When autotx is set in “Register 08. Operating & Function Control 2," the transceiver will automatically enter the TX
state when the TX FIFO almost full threshold is exceeded. Packets will be transmitted according to the configured
packet length. To stop transmitting, clear the packet sent or TX FIFO almost empty interrupts must be cleared by
reading register.
38
Rev 1.1