M306N5FCTFP Renesas Electronics America, M306N5FCTFP Datasheet - Page 283

IC M16C MCU FLASH 100QFP

M306N5FCTFP

Manufacturer Part Number
M306N5FCTFP
Description
IC M16C MCU FLASH 100QFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/6Nr
Datasheets

Specifications of M306N5FCTFP

Core Processor
M16C/60
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, I²C, IEBus, SIO, UART/USART
Peripherals
DMA, WDT
Number Of I /o
87
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
5K x 8
Voltage - Supply (vcc/vdd)
4.2 V ~ 5.5 V
Data Converters
A/D 26x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M306N5FCTFP
Manufacturer:
ON
Quantity:
36 000
Part Number:
M306N5FCTFP#U0
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M306N5FCTFP#UK
Manufacturer:
XILINX
Quantity:
1 400
Part Number:
M306N5FCTFP#UK
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
M306N5FCTFP#UK
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M306N5FCTFP#UKJ
Manufacturer:
Renesas Electronics America
Quantity:
10 000
M16C/6N Group (M16C/6N5)
Rev.2.40
REJ09B0011-0240
Figure 21.8 Program Command
21.3.5.4 Program Command (40h)
The program command writes 2-byte data to the flash memory.
By writing xx40h in the first bus cycle and data to the write address in the second bus cycle, an
auto-program operation (data program and verify) will start. The address value specified in the first bus
cycle must be the same even address as the write address specified in the second bus cycle.
The FMR00 bit in the FMR0 register indicates whether an auto-program operation has been completed.
The FMR00 bit is set to 0 (busy) during auto-programming and to 1 (ready) when an auto-program
operation is completed.
After the completion of an auto-program operation, the FMR06 bit in the FMR0 register indicates
whether or not the auto-program operation has been completed as expected. (Refer to 21.3.8 Full
Status Check.)
An address that is already written cannot be altered or rewritten.
Figure 21.8 shows a flow chart of the Program Command.
The lock bit protects each block from being programmed inadvertently. (Refer to 21.3.6 Data Protect
Function.)
In EW1 mode, do not execute this command on the block where the rewrite control program is allocated.
In EW0 mode, the MCU enters read status register mode as soon as an auto-program operation starts.
The status register can be read. The SR7 bit in the status register is set to 0 at the same time an
auto-program operation starts. It is set to 1 when auto-program operation is completed. The MCU remains in
read status register mode until the read array command is written. After completion of an auto-program
operation, the status register indicates whether or not the auto-program operation has been completed
as expected.
Apr 14, 2006
page 261 of 372
NOTE:
1.Write the command code and data to even addresses.
Write the command code xx40h
to an address to be the written
Write data to an address
to be written
Program operation is
completed
Full status check
FMR00=1?
Start
YES
NO
21. Flash Memory Version