HD6417705F133BV Renesas Electronics America, HD6417705F133BV Datasheet - Page 510

MPU 3V 0K PB-FREE 208 FP

HD6417705F133BV

Manufacturer Part Number
HD6417705F133BV
Description
MPU 3V 0K PB-FREE 208 FP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417705F133BV

Core Processor
SH-3
Core Size
32-Bit
Speed
133MHz
Connectivity
EBI/EMI, FIFO, IrDA, SCI, USB
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
105
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.4 V ~ 1.6 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
208-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
18.4.5
EP2 has two 64-byte FIFOs, but the user can transmit data and write transmit data without being
aware of this dual-FIFO configuration. However, one data write is performed for one FIFO. For
example, even if both FIFOs are empty, it is not possible to perform EP2PKTE at one time after
consecutively writing 128 bytes of data. EP2PKTE must be performed for each 64-byte write.
When performing bulk-in transfer, as there is no valid data in the FIFOs on reception of the first
IN token, an EP2TR bit interrupt in IFR0 is requested. With this interrupt, 1 is written to the
EP2EMPTY bit in IER0, and the EP2 FIFO empty interrupt is enabled. At first, both EP2 FIFOs
are empty, and so an EP2 FIFO empty interrupt is generated immediately.
The data to be transmitted is written to the data register using this interrupt. After the first transmit
data write for one FIFO, the other FIFO is empty, and so the next transmit data can be written to
the other FIFO immediately. When both FIFOs are full, EP2 EMPTY is cleared to 0. If at least one
FIFO is empty, the EP2EMPTY bit in IFR0 is set to 1. When ACK is returned from the host after
Rev. 2.00, 09/03, page 462 of 690
EP2 Bulk-In Transfer (Dual FIFOs)
Data transmission to host
Clear EP2 empty status
(IFR0.EP2 EMPTY = 0)
IN token reception
in EP2 FIFO?
in EP2 FIFO?
Valid data
Space
Figure 18.11 EP2 Bulk-In Transfer Operation
Yes
No
ACK
USB function
No
Yes
NACK
empty status
EMPTY = 1)
(IFR0.EP2
Set EP2
Interrupt request
Interrupt
request
Write one packet of data
(IER0.EP2 EMPTY = 1)
Write 1 to EP2 packet
(TRG.EP2 PKTE = 1)
to EP2 data register
Clear EP2 transfer
(IFR0.EP2 TR = 0)
Application
IER0.EP2 EMPTY
Enable EP2 FIFO
empty interrupt
request flag
enable bit
(EPDR2)
interrupt

Related parts for HD6417705F133BV