PIC18F4431-E/PT Microchip Technology, PIC18F4431-E/PT Datasheet - Page 165

IC MCU FLASH 8KX16 44TQFP

PIC18F4431-E/PT

Manufacturer Part Number
PIC18F4431-E/PT
Description
IC MCU FLASH 8KX16 44TQFP
Manufacturer
Microchip Technology
Series
PIC® 18Fr

Specifications of PIC18F4431-E/PT

Core Size
8-Bit
Program Memory Size
16KB (8K x 16)
Oscillator Type
Internal
Core Processor
PIC
Speed
40MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, LVD, Power Control PWM, QEI, POR, PWM, WDT
Number Of I /o
36
Program Memory Type
FLASH
Eeprom Size
256 x 8
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
4.2 V ~ 5.5 V
Data Converters
A/D 9x10b
Operating Temperature
-40°C ~ 125°C
Package / Case
44-TQFP, 44-VQFP
Controller Family/series
PIC18
No. Of I/o's
36
Eeprom Memory Size
256Byte
Ram Memory Size
768Byte
Cpu Speed
40MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F4431-E/PT
Manufacturer:
JOHANSON
Quantity:
24 000
Part Number:
PIC18F4431-E/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
The three Input Capture channels are controlled
through
CAP1CON, CAP2CON, and CAP3CON. Each channel
is configured independently with its dedicated register.
The implementation of the registers is identical, except
for the Special Event trigger (see Section 16.1.8 “Spe-
cial Event Trigger (CAP1 Only)”). The typical Capture
Control register is shown in Register 16-1.
REGISTER 16-1:
 2003 Microchip Technology Inc.
Note:
the
bit 7
bit 6
bit 5
bit 4
bit 3-0
Throughout this section, references to
registers and bit names that may be asso-
ciated with a specific capture channel will
be referred to generically by the use of the
term ‘x’ in place of the channel number.
For example, ‘CAPxREN’ may refer to the
Capture Reset Enable bit in CAP1CON,
CAP2CON or CAP3CON.
Input
CAPxCON: INPUT CAPTURE CONTROL REGISTER
bit 7
Unimplemented: Read as ‘0’
CAPxREN: Time Base Reset Enable bit
1 = Enabled
0 = Disable selected time base Reset on capture.
Unimplemented: Read as ‘0’
Unimplemented: Read as ‘0’
CAPxM3:CAPxM0: Input Capture 1 (ICx) Mode Select bits
1111 = Special Event Trigger mode. The trigger occurs on every rising edge on CAP1 input
1110 = Special Event Trigger mode. The trigger occurs on every falling edge on CAP1 input
1101 = Unused
1100 = Unused
1011 = Unused
1010 = Unused
1001 = Unused
1000 = Capture on every CAPx input state change
0111 = Pulse Width Measurement mode, every rising to falling edge
0110 = Pulse Width Measurement mode, every falling to rising edge
0101 = Frequency Measurement mode, every rising edge
0100 = Capture mode, every 16th rising edge
0011 = Capture mode, every 4th rising edge
0010 = Capture mode, every rising edge
0001 = Capture mode, every falling edge
0000 = Input Capture 1 (ICx) off
Capture
Legend:
R = Readable bit
- n = Value at POR
Note 1: Special Event Trigger is only available on CAP1. For CAP2 and CAP3, this config-
U-0
Control
CAPxREN
uration is unused.
R/W-0
Registers
PIC18F2331/2431/4331/4431
U-0
Preliminary
W = Writable bit
‘1’ = Bit is set
R/W-0
When in Counter mode, the counter must be
configured
(TMR5SYNC = 0). When configured in Asynchronous
mode, the IC module will not work properly.
CAPxM3
R/W-0
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
as
the
CAPxM2
R/W-0
synchronous
CAPxM1
x = Bit is unknown
R/W-0
DS39616B-page 163
counter
CAPxM0
R/W-0
bit 0
only
(1)
(1)