ADE5166_08 AD [Analog Devices], ADE5166_08 Datasheet - Page 41

no-image

ADE5166_08

Manufacturer Part Number
ADE5166_08
Description
Single-Phase Energy Measurement IC with 8052 MCU, RTC, and LCD Driver
Manufacturer
AD [Analog Devices]
Datasheet
Table 39. Calibration Mode Register (CALMODE, Address 0x3D)
Bit
[7:6]
[5:4]
3
2
[1:0]
INTERRUPT STATUS/ENABLE SFRS
Table 40. Interrupt Status 1 SFR (MIRQSTL, Address 0xDC)
Bit
7
6
5
4
3
2
1
0
1
Table 41. Interrupt Status 2 SFR (MIRQSTM, Address 0xDD)
Bit
7
6
5
4
3
2
1
0
1
Table 42. Interrupt Status 3 SFR (MIRQSTH, Address 0xDE)
Bit
7
6
5
4
3
2
1
0
This function is not available in the ADE5166.
This function is not available in the ADE5166.
Interrupt Flag
RESET
Reserved
WFSM
PKI
PKV
CYCEND
ZXTO
ZX
Interrupt Flag
CF2
CF1
VAEOF
REOF
AEOF
VAEHF
REHF
AEHF
Mnemonic
Reserved
SEL_I_CH
V_CH_SHORT
I_CH_SHORT
Reserved
Interrupt Flag
ADEIRQFLAG
Reserved
FAULTSIGN
VARSIGN
APSIGN
VANOLOAD
RNOLOAD
APNOLOAD
1
1
1
1
Indicates the end of a reset (for both software and hardware reset).
Logic 1 indicates that the voltage channel has exceeded the VPKLVL value.
0
0
0
Description
This bit is set if any of the ADE status flags that are enabled to generate an ADE interrupt is set. This bit is
automatically cleared when all of the enabled ADE status flags are cleared.
Reserved.
Logic 1 indicates that the fault mode has changed according to the configuration of the ACCMODE register.
Logic 1 indicates that the reactive power sign has changed according to the configuration of the ACCMODE register.
Logic 1 indicates that the active power sign has changed according to the configuration of the ACCMODE register.
Logic 1 indicates that an interrupt has been caused by apparent power no load detection. This interrupt is also
used to reflect that the part is entering the I
Logic 1 indicates that an interrupt has been caused by reactive power no load detection.
Logic 1 indicates that an interrupt has been caused by active power no load detection.
Description
Logic 1 indicates that a pulse on CF2 has been issued. The flag is set even if the CF2 pulse output is not
enabled by clearing Bit 2 of the MODE1 register.
Logic 1 indicates that a pulse on CF1 has been issued. The flag is set even if the CF1 pulse output is not
enabled by clearing Bit 1 of the MODE1 register.
Logic 1 indicates that the VAHR register has overflowed.
Logic 1 indicates that the VARHR register has overflowed.
Logic 1 indicates that the WATTHR register has overflowed.
Logic 1 indicates that the VAHR register is half full.
Logic 1 indicates that the VARHR register is half full.
Logic 1 indicates that the WATTHR register is half full.
Description
Reserved.
Logic 1 indicates that new data is present in the waveform registers (Address 0xE2 to Address 0xE7).
Logic 1 indicates that the current channel has exceeded the IPKLVL value
Logic 1 indicates the end of the energy accumulation over an integer number of half-line cycles.
Logic 1 indicates that no zero crossing on the line voltage happened for the last ZXTOUT half-line cycles.
Logic 1 indicates detection of a zero crossing in the voltage channel.
Default
0
0
Description
These bits must be kept at 0 for proper operation.
These bits define the current channel used for energy measurements.
SEL_I_CH
00
01
10
11
Logic 1 shorts the voltage channel to ground.
Logic 1 shorts the voltage channel to ground.
These bits must be kept at 0 for proper operation.
Rev. 0 | Page 41 of 148
Current channel automatically selected by the tampering condition
Current channel connected to I
Current channel connected to I
Current channel automatically selected by the tampering condition
Result
rms
no load mode.
PA
PB
ADE5166/ADE5169