ADE5166/ADE5169
Address
MADDPT[6:0]
0x29
0x2A
0x2B
0x3B
0x3C
0x3D
0x3E
0x3F
1
ENERGY MEASUREMENT INTERNAL REGISTER DETAILS
Table 32. Mode 1 Register (MODE1, Address 0x0B)
Bit
7
6
5
4
3
2
1
0
Table 33. Mode 2 Register (MODE2, Address 0x0C)
Bit
[7:6]
[5:4]
3
2
1
0
1
This function is not available in the ADE5166.
This function is not available in the ADE5166.
Mnemonic
SWRST
DISZXLPF
INTE
SWAPBITS
PWRDN
DISCF2
DISCF1
DISHPF
Mnemonic
CF2SEL
CF1SEL
VARMSCFCON
ZXRMS
FREQSEL
WAVEN
Mnemonic
CF2NUM
CF2DEN
MODE3
Reserved
Reserved
CALMODE
Reserved
Reserved
Default
0
0
0
0
0
1
1
0
R/W
R/W
R/W
R/W
R/W
Default
01
00
0
0
0
0
Description
Setting this bit resets all of the energy measurement registers to their default values.
Setting this bit disables the zero-crossing low-pass filter.
Setting this bit enables the digital integrator for use with a di/dt sensor.
Setting this bit swaps CH1 ADC and CH2 ADC.
Setting this bit powers down voltage and current ADCs.
Setting this bit disables Frequency Output CF2.
Setting this bit disables Frequency Output CF1.
Setting this bit disables the HPFs in voltage and current channels.
8
8
Length
(Bits)
16
16
Signed/
Unsigned
U
U
U
U
Description
Configuration bits for CF2 output.
CF2SEL
00
01
1X
Configuration bits for CF1 output.
CF1SEL
00
01
1X
Configuration bits for apparent power or I
(VAHR, RVAHR, and LVAHR). Note that CF1 cannot be proportional to VA if CF2 is proportional to
I
VARMSCFCON
0
1
Logic 1 enables update of rms values synchronously to Voltage ZX.
Configuration bits to select period or frequency measurement for PER_FREQ register
(Address 0x0A).
FREQSEL
0
1
When this bit is set, waveform sampling mode is enabled.
rms
and vice versa.
Rev. 0 | Page 38 of 148
Default
0
0x003F
0
0
0x0300
0
0
0
Result
CF2 frequency is proportional to active power.
CF2 frequency is proportional to reactive power.
CF2 frequency is proportional to apparent power or I
Result
CF1 frequency is proportional to active power.
CF1 frequency is proportional to reactive power.
CF1 frequency is proportional to apparent power or I
Result
If CF1SEL[1:0] = 1X, CF1 is proportional to VA
If CF2SEL[1:0] = 1X, CF2 is proportional to VA
If CF1SEL[1:0] = 1X, CF1 is proportional to I
If CF2SEL[1:0] = 1X, CF2 is proportional to I
Result
PER_FREQ register holds a period measurement
PER_FREQ register holds a frequency measurement
Description
Sets CF2 numerator register.
Sets CF2 denominator register.
Enables zero crossing outputs (see Table 38).
This register must be set to its default value for proper operation.
This register must be set to its default value for proper operation.
Sets calibration mode (see Table 39).
This register must be set to its default value for proper operation.
This register must be set to its default value for proper operation.
rms
for CF1, CF2 outputs, and VA accumulation registers
rms
rms
1
1
rms
rms
.
.

Related parts for ADE5166_08