DS26518GNB1+ Maxim Integrated Products, DS26518GNB1+ Datasheet - Page 148

IC TXRX T1/E1/J1 8PRT 256-CSBGA

DS26518GNB1+

Manufacturer Part Number
DS26518GNB1+
Description
IC TXRX T1/E1/J1 8PRT 256-CSBGA
Manufacturer
Maxim Integrated Products
Type
Transceiverr
Datasheet

Specifications of DS26518GNB1+

Number Of Drivers/receivers
8/8
Protocol
T1/E1/J1
Voltage - Supply
3.135 V ~ 3.465 V
Mounting Type
Surface Mount
Package / Case
256-CSBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 4: Receive SLC-96 Synchronizer Enable (RSLC96). See Section
BITS 3 AND 2: OUT OF FRAME SELECT BITS (OOF[2:1])
Bit 1: Receive RAI Integration Enable (RAIIE). The ESF RAI indication can be interrupted for a period not to
exceed 100ms per interruption (T1.403). In ESF mode, setting RAIIE will cause the RAI status from the DS26518
to be integrated for 200ms.
Bit 0: Receive-Side Remote Alarm Select (RRAIS)
OOF2
0
0
1
1
0 = The SLC-96 synchronizer is disabled.
1 = The SLC-96 synchronizer is enabled.
0 =
1 =
0 = Receive framer detects T1 remote alarm.
1 = Receive Framer detects J1 Remote Alarm.
OOF1
0
1
0
1
7
0
RAI clears when 14 or fewer patterns of 00FF hex out of 16 possible appear in the FDL.
RAI clears when the condition has been absent for greater than 200ms.
D4—Zeros in bit 2 of all channels.
ESF—00FF pattern in FDL.
D4—A one in the S-bit position of frame 12.
ESF—all ones in FDL.
RAI detects when 16 consecutive patterns of 00FF appear in the FDL.
RAI detects when the condition has been present for greater than 200ms.
OUT OF FRAME CRITERIA
2/4 frame bits in error
2/5 frame bits in error
2/6 frame bits in error
2/6 frame bits in error
T1RCR2 (T1 Mode)
Receive Control Register 2
014h + (200h x (n - 1)) : where n = 1 to 8
6
0
5
0
RSLC96
148 of 312
0
4
OOF2
3
0
9.9.4.4
for SLC-96 details.
OOF1
2
0
RAIIE
1
0
RRAIS
0
0

Related parts for DS26518GNB1+