82P2282PF IDT, Integrated Device Technology Inc, 82P2282PF Datasheet - Page 326

82P2282PF

Manufacturer Part Number
82P2282PF
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of 82P2282PF

Screening Level
Industrial
Pin Count
100
Mounting
Surface Mount
Package Type
TQFP
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Not Compliant
E1 Alarm Status (0B9H, 1B9H)
TS16LOSV:
TS16AISV:
RMAIV:
AIS:
the AISC bit (b1, E1-0BCH,...) is ‘1’, more than 2 zeros are detected in each of 2 consecutive 512-bit fixed window.
is out of Basic frame synchronization; when the AISC bit (b1, E1-0BCH,...) is ‘1’, less than 3 zeros are detected in each of 2 consecutive 512-bit fixed
window.
RAIV:
0BCH,...) is ‘1’, a single A bit is received as ‘0’.
(b0, E1-0BCH,...) is ‘1’, a single A bit is received as ‘1’.
RED:
Programming Information
IDT82P2282
Bit Name
Default
Bit No.
Type
The LOS in TS16 is detected on the base of Basic frame synchronization.
= 0: The LOS in TS16 is cleared when 16 consecutive TS16 are not all received as ‘0’.
= 1: The LOS in TS16 is detected when 16 consecutive TS16 are all received as ‘0’.
The AIS in TS16 is detected on the base of Basic frame synchronization.
= 0: The AIS in TS16 is cleared when TS16 contains more than 3 zeros in a 16-consecutive-Basic-frame period.
= 1: The AIS in TS16 is detected when TS16 contains less than 4 zeros in each of two 16-consecutive-Basic-frame periods.
The Remote Signaling Multi-Frame alarm is detected on the base of CAS Signaling Multi-Frame synchronization.
= 0: The Remote Signaling Multi-Frame alarm is cleared when a single Y bit is received as ‘0’.
= 1: The Remote Signaling Multi-Frame alarm is detected when 3 consecutive Y bits are received as ‘1’.
= 0: The AIS alarm is cleared. That is, when the AISC bit (b1, E1-0BCH,...) is ‘0’, more than 2 zeros are detected in a 512-bit fixed window; when
= 1: The AIS alarm is detected. That is, when the AISC bit (b1, E1-0BCH,...) is ‘0’, less than 3 zeros are detected in a 512-bit fixed window and it
The Remote alarm is detected on the base of Basic frame synchronization.
= 0: The Remote alarm is cleared. That is, when the RAIC bit (b0, E1-0BCH,...) is ‘0’, a single A bit is received as ‘0’; when the RAIC bit (b0, E1-
= 1: The Remote alarm is detected. That is, when the RAIC bit (b0, E1-0BCH,...) is ‘0’, 4 consecutive A bits are received as ‘1’; when the RAIC bit
= 0: The RED alarm is cleared when in Basic frame synchronization persists for 100ms.
= 1: The RED alarm is detected when out of Basic frame synchronization persists for 100ms.
7
Reserved
6
TS16LOSV
R
5
0
TS16AISV
R
4
0
326
DUAL T1/E1/J1 LONG HAUL / SHORT HAUL TRANSCEIVER
RMAIV
R
3
0
AIS
R
2
0
RAIV
R
1
0
August 20, 2009
RED
R
0
0