CV500BC051 Omron, CV500BC051 Datasheet - Page 337

no-image

CV500BC051

Manufacturer Part Number
CV500BC051
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500BC051

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
312
Error Log
0003
Hex
0004
Hex
0005
Hex
0006
Hex
000D
Hex
000E
Hex
000F
Hex
0010
Hex
0011
Hex
0012
Hex
0013
Hex
Error
code
PLC shared RAM error
CPU Bus Unit ID number error
Unit number error
CPU Unit error
PLC model error
I/O Bus error
PLC initialization error
PLC Setup exceeds capacity
PLC initialization error
(Time out)
CPU Unit memory error
CPU Unit write-protected
Contents
01 Hex:
Cyclic
02 Hex:
Event
04 Hex:
CPU bus link
00 Hex
Unit set
value
Bit 11:No relevant Unit in
Bit 12: Hardware test unit
Bit 13: Incorrect unit num-
Bit 14: Duplicated unit
Not set
00 Hex
01 Hex:
Read error
02 Hex:
Write error
1st byte
I/O table.
number recognized.
ber.
number.
Detail code
00 Hex
00 Hex
The value
recognized
by the CPU
Unit
00 Hex
01 Hex:
Data link
table
02 Hex: Net-
work param-
eters
03 Hex:
Routing
table
04 Hex: PLC
Setup Area
2nd byte
Check operating
environment.
Check I/O
Connecting Cables.
Check the Unit
number setting. Rec-
reate the I/O table.
Check the Unit num-
ber settings. Recre-
ate the I/O table.
Refer to 1-2-4 Con-
troller Link Unit Mod-
els and PLCs and
PLCs and check the
PLC model.
Check the operating
environment.
Check the operating
environment.
Reduce the number
of CPU Bus Units
mounted on each
CPU Unit by one.
Check the operating
environment.
Reset the appropri-
ate data.
Release the CPU
Unit write protect.
Correction
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Written to
EEPROM
Section 9-3
CV
CV, CS/CJ
CV
CV, CS/CJ
C200HX/HG/
HE
CS/CJ
CS/CJ
CS/CJ
CS/CJ
CS/CJ
CS/CJ
Applicable
PLC

Related parts for CV500BC051