Specifications of CV500BC051

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Setting Data Links
Area for area 2
Send size per node for
area 2
First word to store link
status
Nodes to participate in
the data links
Note a) The total number of words in data link send and receive areas
Item
b) The following values must be satisfied for each node for the data
c) When using area 1 only, set the data link start word, type, and
d) When using area 2 only, set the data link start word, type, and
e) The startup node must be set as a participating node of the data
must not exceed 20,000 per node when using Controller Link
Units with unit Ver. 1.2 or later, or 12,000 words per node if using
pre-Ver. 1.2 Controller Link Units.
link area 1 and area 2 so that the final word in the data link does
not go beyond the last word in the PLC memory area.
(Data link start word – 1) + Total number of send/receive
words in area
the number of send words of area 2 to 0.
the number of send words of area 1 to 0.
links. If not, the data links will not start.
Set the area for area 2 in BCD.
DM Area: 82
EM Area: Banks 00 to 07: 90 to 97
Area 2 not used: 00
Set the number of words in BCD between 0 and 1,000.
The total number of send words of area 1 and area 2
must not exceed 1,000.
When area 2 is not used, set to 0.
Set in BCD the first word used for storing data link status.
An area of 16 words is used for storing status.
0 (*), IR 000 to IR 6128
Status is stored in the IR or CIO Area only.
*: When 0 is set, the status is saved in IR 1500 + unit
Turn ON the bits corresponding to the nodes participating
in the data links.
The data link will not start unless the startup node itself is
set as a participating node.
The data link will not start if the node is set to a parameter
exceeding the maximum node address of the network
parameter.
number x 25 (+ 7 to + 22).
Banks 08 to 12: A8 to AC
6143 (CIO Area)
199 (LR Area)
32767 (DM Area, EM Area)
Setting range
Section 5-2
135