CV500BC051 Omron, CV500BC051 Datasheet - Page 177
CV500BC051
Manufacturer Part Number
CV500BC051
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet
1.CV500BC031.pdf
(403 pages)
Specifications of CV500BC051
Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
- Current page: 177 of 403
- Download datasheet (5Mb)
CQM1H-series Startup Node
Settings
152
Setting Data Links
DM 6400
DM 6401
DM 6402
DM 6403
DM 6404
DM 6405
DM 6406
DM 6407
DM 6408
DM 6409
0: Always 0.
– : Other settings
15 14 13 12 11 10 9
15
15 14 13 12 11 10 9
16 15 14 13 12 11 10 9
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
–
BCD: Set the value as binary-coded decimal.
Area 1 data link start word (BCD)
Area 1 type
Number of send words per node of area 1 (BCD)
Rightmost 4 digits of data link start word of area 2 (BCD)
Area 2 type
Number of send words per node of area 2 (BCD)
First data link status word (BCD)
–
0
–
0
0
0
Set the following DM Parameter Area of the PLC of the startup node.
Data link mode
Area 1 data link start
word
Area 1 type
Send size (number of
words) for node of area 1
Area 2 data link start
word
Area 2 type
Send size (number of
words) for node of area 2
8
0
8
8
Leftmost digit of data link start word
of area 2 (BCD)
7
0
7
7
8
00
6
0
6
7
Item
5
5
6
4
4
5
3
0
3
4
2
0
2
3
1
0
1
2
Specify automatic (01).
Set the word address in BCD.
IR Area: IR 0000 to IR 247
LR Area: LR 00 to LR 63
Set the area for area 1 in BCD.
IR Area:
LR Area:
Area 1 not used: 00
Set the number of words in BCD between 0 and 1,000.
The total number of send words of area 1 and area 2
must not exceed 1,000.
When area 1 is not used, set to 0.
Set the word address in BCD.
DM Area: DM 0000 to DM 5999
EM Area: EM 0000 to EM 6143 (EM must be installed)
Set the area for area 2 in BCD.
DM Area: 82
EM Area: 90
Area 2 not used: 00
Set the number of words in BCD between 0 and 1,000.
The total number of send words of area 1 and area 2
must not exceed 1,000.
When area 2 is not used, set to 0.
Data link mode
Set to 01 for automatic setting.
(00 is for manual setting. Other values are invalid.)
0
0
0
1
0
The numbers indicate node numbers.
The value assigned indicates whether the
node is to participate in the data links.
Participate:
Not participate: 0
80
86
Nodes to participate in the data links
Setting range
1
Section 5-2
Related parts for CV500BC051
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: