78M6610+PSU/EK#1 Maxim Integrated, 78M6610+PSU/EK#1 Datasheet - Page 44

no-image

78M6610+PSU/EK#1

Manufacturer Part Number
78M6610+PSU/EK#1
Description
Development Boards & Kits - Other Processors 78M6610 EVAL KIT
Manufacturer
Maxim Integrated
Datasheet

Specifications of 78M6610+PSU/EK#1

Rohs
yes
Part # Aliases
90-X6610#KK1
78M6610+PSU Data Sheet
Table 18 lists the commands that are supported by the 78M6610+PSU.
Slave Packets
The 78M6610+PSU replies to the host processor either with an acknowledge (either ACK or NACK) or
with data. The format of slave packets depends upon the type of response to the master device.
Table 19 lists the reply codes and their meanings.
44
Command
E1 – EF
C1 - CE
D1 - DF
A4 - AF
B0 - BF
F0 - FF
80 - 9F
0 - 7F
CF
A0
A1
A2
A3
C0
D0
E0
- timeout -
Code
0xAD
0xBC
0xBD
0xAA
0xAE
0xB0
0xBF
[byte-L][byte-H]
Parameters
Acknowledge with data.
Auto Reporting Header (with data).
Acknowledge without data.
Negative Acknowledge (NACK).
Command not implemented.
Checksum failed.
Buffer overflow (or packet too long).
Any condition too difficult to handle with a reply.
[byte-H]
[byte-L]
[data...]
[data...]
[byte]
[byte]
(invalid)
(not used)
Clear address
Set Read/Write address bits [7:0]
Set Read/Write address bits [15:8]
Set Read/Write address bits [15:0]
(reserved for larger address targets)
(not used)
De-select Target (target will Acknowledge)
Select target 1 to 14
Select target 0 to 255
Write bytes set by remainder of Byte Count
Write 1 to 15 bytes
Read 0 to 255 bytes
Read 1 to 15 bytes
(not used)
Table 19: Slave Reply Codes
Table 18: Host Commands
Definition
Description
Rev 1