78M6610+PSU/EK#1 Maxim Integrated, 78M6610+PSU/EK#1 Datasheet

no-image

78M6610+PSU/EK#1

Manufacturer Part Number
78M6610+PSU/EK#1
Description
Development Boards & Kits - Other Processors 78M6610 EVAL KIT
Manufacturer
Maxim Integrated
Datasheet

Specifications of 78M6610+PSU/EK#1

Rohs
yes
Part # Aliases
90-X6610#KK1
DESCRIPTION
The 78M6610+PSU is a single-core energy measurement
processor for single-phase power supplies. It is designed
specifically for real-time monitoring at the input of AC/DC
power converters used in data centers and IT server rooms.
It is available in either a 24-pin QFN or 16-pin TSSOP
package for optimal space savings.
The 78M6610+PSU provides four analog inputs (two
differential and two single ended) for interfacing to voltage,
current, and two optional temperature sensors. Scaled
voltages from the sensors are fed to the single converter
front-end utilizing a high-resolution delta-sigma converter.
An embedded 24-bit energy measurement processor (EMP)
and firmware performs all the necessary computation,
compensation, and data formatting for accurate, real-time
reporting to the host. With integrated flash memory, the
78M6610+PSU is a completely autonomous solution
capable of storing nonvolatile data such as calibration
coefficients and input configuration settings.
The 78M6610+PSU is designed to interface to the host
processor via the UART interface. Alternatively, SPI or I
may also be used. Supported current sensors include
Current Transformers (CT) and Resistive Shunts.
Rev 1
Thermistor
Thermistor
Voltage
Current
Sensor
Sensor
MUX
Single Converter
Front End
ADC
78M6610+PSU
Measurement
Processor
FLASH
2
RAM
C
for Single-Phase Power-Supply Units
FEATURES
• Delta-sigma ADC with precision voltage
• Internal or external oscillator timing reference
• SPI, I
• 24-bit energy measurement processor (EMP)
reference
o
o
o
o
o
configurable I/O pins for alarm signaling,
address pins, or user control
with integrated firmware and flash memory
provides the user with:
Energy Measurement Processor
UART
True RMS calculations for current,
voltage, line frequency, real power,
reactive power, apparent power, and
power factor
Compensation for ambient temperature,
sensor tolerances, offsets, and EMI filter
components
Real-time data accumulation based on an
integer number of AC cycles
Quick calibration routines for
manufacturability
Up to two voltage inputs for optional
connection to thermal sensors
SPI
I2C
2
C, or UART interface options with
Digital
I/O
DATA SHEET
19-6396; Rev 1; 2/13
Controller
78M6610+PSU
Host
1

Related parts for 78M6610+PSU/EK#1

Related keywords