SC16IS740IPW PHILIPS [NXP Semiconductors], SC16IS740IPW Datasheet - Page 26

no-image

SC16IS740IPW

Manufacturer Part Number
SC16IS740IPW
Description
Single UART with I2C-bus/SPI interface, 64 bytes of transmit and receive FIFOs, IrDA SIR built-in support
Manufacturer
PHILIPS [NXP Semiconductors]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16IS740IPW
Quantity:
949
Part Number:
SC16IS740IPW
Manufacturer:
NXP
Quantity:
505
Part Number:
SC16IS740IPW
Manufacturer:
NXP
Quantity:
20 000
Part Number:
SC16IS740IPW
0
Part Number:
SC16IS740IPW,112
Manufacturer:
JAMICON
Quantity:
101
Part Number:
SC16IS740IPWR
Manufacturer:
TI/德州仪器
Quantity:
20 000
NXP Semiconductors
SC16IS740_750_760_5
Product data sheet
8.5 Line Status Register (LSR)
Table 16
Table 16.
When the LSR is read, LSR[4:2] reflect the error bits (BI, FE, PE) of the character at the
top of the RX FIFO (next character to be read). Therefore, errors in a character are
identified by reading the LSR and then reading the RHR.
LSR[7] is set when there is an error anywhere in the RX FIFO, and is cleared only when
there are no more errors remaining in the FIFO.
Bit
7
6
5
4
3
2
1
0
Symbol
LSR[7]
LSR[6]
LSR[5]
LSR[4]
LSR[3]
LSR[2]
LSR[1]
LSR[0]
shows the Line Status Register bit settings.
Line Status Register bits description
Description
FIFO data error.
THR and TSR empty. This bit is the Transmit Empty indicator.
THR empty. This bit is the Transmit Holding Register Empty indicator.
break interrupt
framing error
parity error.
overrun error
data in receiver
Rev. 05 — 16 November 2006
Single UART with I
logic 0 = no error (normal default condition)
logic 1 = at least one parity error, framing error, or break indication is in the
receiver FIFO. This bit is cleared when no more errors are present in the
FIFO.
logic 0 = transmitter hold and shift registers are not empty
logic 1 = transmitter hold and shift registers are empty
logic 0 = transmit hold register is not empty
logic 1 = transmit hold register is empty. The host can now load up to
64 characters of data into the THR if the TX FIFO is enabled.
logic 0 = no break condition (normal default condition)
logic 1 = a break condition occurred and associated character is 0x00, that
is, RX was LOW for one character time frame
logic 0 = no framing error in data being read from RX FIFO (normal default
condition).
logic 1 = framing error occurred in data being read from RX FIFO, that is,
received data did not have a valid stop bit
logic 0 = no parity error (normal default condition)
logic 1 = parity error in data being read from RX FIFO
logic 0 = no overrun error (normal default condition)
logic 1 = overrun error has occurred
logic 0 = no data in receive FIFO (normal default condition)
logic 1 = at least one character in the RX FIFO
2
C-bus/SPI interface, 64-byte FIFOs, IrDA SIR
SC16IS740/750/760
© NXP B.V. 2006. All rights reserved.
26 of 62