pxf4336 Infineon Technologies Corporation, pxf4336 Datasheet - Page 357

no-image

pxf4336

Manufacturer Part Number
pxf4336
Description
Abm Premium Atm Buf Fer Manager
Manufacturer
Infineon Technologies Corporation
Datasheet
SOCER
BUFER2
BUFER3
CDVOV
MUXOV
AAL5COL
RMCER
BIP8ER
Data Sheet
Start of Cell Error at UTOPIA Receive Upstream (PHY) Interface
detected.
Unexpected Buffer Error number 2. Should never occur in normal
operation. Immediate reset of the chip is recommended.
Unexpected Buffer Error number 3. Should never occur in normal
operation. Immediate reset of the chip is recommended.
The maximum upstream CDV value for shaped connections given
in CDVU register has been exceeded. This interrupt is a notification
only; that is, no cells are discarded due to this event.
Indicates that a Scheduler Block lost a serving time slot. (Can
indicate a static backpressure on one port).
The ’MUXOV’ interrupt is generated when the number of lost
serving time slots exceeds the number specified in bit field
MaxBurstS(3:0) (see register UECRI/DECRI).
No further action is required upon this interrupt.
Indicates that an interrupt event occurred in the upstream AAL5
unit. The interrupt reason must be read from the AAL5 status
register
RM Cell received with corrupted CRC-10.
BIP-8 error detected when reading a cell from the upstream external
SDRAM. BIP-8 protects the cell header of each cell. The cell is
discarded. One single sporadic event can be ignored. Hardware
should be taken out of service when the error rate exceeds 10
“UA5SARS/DA5SARS” on Page 210
357
Register Description
(upstream).
PXF 4336 V1.1
2001-12-17
ABM-P