Table 2: LAN100 Registers
PNX17XX_SER_1
Preliminary data sheet
Bit
0
Offset 0x07 2040
31:16
15:8
7:0
Offset 0x07 2044
31:16
15:8
7:0
Offset 0x07 2048
31:16
15:8
7:0
Offset 0x07 2100
31:12
11
10
9
8
7
6
5
4
3
2
1
0
Offset 0x07 2104
Symbol
BUSY
-
STATION_ADDRESS_
1ST_OCTET
STATION_ADDRESS__
2ND_OCTET
-
STATION_ADDRESS_
3RD_OCTET
STATION_ADDRESS_
4TH_OCTET
-
STATION_ADDRESS_
5TH_OCTET
STATION_ADDRESS_
6TH_OCTET
-
EnableQoS
FullDuplex
RMII
TxFlowControl
PassRxFilter
PassRuntFrame
RxReset
TX RESET
RegReset
TxRtEnable
TxEnable
RxEnable
Station Address (SA0)
Station Address (SA1)
Station Address (SA2)
Command Register (Command)
Status Register (Status)
…Continued
Acces
s
RO
-
R/W
R/W
-
R/W
R/W
-
R/W
R/W
-
R/W
R/W
R/W
R/W
R/W
R/W
WO
WO
WO
R/W
R/W
R/W
Value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Rev. 1 — 17 March 2006
Description
When set, this bit indicates the MII Management module is currently
performing an MII Management read or write cycle.
Unused
This field holds the first octet of the station address.
This field holds the second octet of the station address.
Unused
This field holds the third octet of the station address.
This field holds the fourth octet of the station address.
Unused
This field holds the fifth octet of the station address.
This field holds the sixth octet of the station address.
Unused
When set, the arbiter operates in QoS mode, in which the real-time
transmit channel has low priority and the non-real-time channel has
high priority
When set, indicates full-duplex operation.
When set, indicates RMII mode; if clear, then MII mode.
Enable IEEE 802.3 / clause 31 flow control sending pause frames in
full duplex and continuous preamble in half duplex.
When set to ‘1’, disables receive filtering, i.e., all packets received
are written to memory.
When set to ‘1’, runt frame packets smaller than 64 bytes are
passed to memory unless they have a CRC error. If set to ‘0’, runt
frames are filtered out.
If set, reset the Receive Datapath.
If set, reset the Transmit Datapath.
If set, reset all datapaths and the host registers. The MII Interface
must be reset separately.
Enable the real-time Transmit Datapath.
Enable the non-real-time Transmit Datapath.
Enable the Receive Datapath.
Chapter 23: LAN100 — Ethernet Media Access Controller
© Koninklijke Philips Electronics N.V. 2006. All rights reserved.
PNX17xx Series