ATmega406 Atmel Corporation, ATmega406 Datasheet - Page 207

no-image

ATmega406

Manufacturer Part Number
ATmega406
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATmega406

Flash (kbytes)
40 Kbytes
Pin Count
48
Max. Operating Frequency
1 MHz
Cpu
8-bit AVR
# Of Touch Channels
8
Hardware Qtouch Acquisition
No
Max I/o Pins
18
Ext Interrupts
4
Usb Speed
No
Usb Interface
No
Twi (i2c)
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
11
Adc Resolution (bits)
12
Adc Speed (ksps)
1.9
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
2
Eeprom (bytes)
512
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-30 to 85
I/o Supply Class
4.0 to 25
Operating Voltage (vcc)
4.0 to 25
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
3
Pwm Channels
2
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATmega406-1AAU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATmega406-1AAU
Manufacturer:
AT
Quantity:
20 000
28.6.12
28.6.13
28.6.14
2548E–AVR–07/06
Reading the Fuse and Lock Bits
Reading the Signature Bytes
Reading the Calibration Byte
The algorithm for reading the Fuse and Lock bits is as follows (refer to
on page 202
1. A: Load Command “0000 0100”.
2. Set OE to “0”, BS2 to “0” and BS1 to “0”. The status of the Fuse Low bits can now be
3. Set OE to “0”, BS2 to “1” and BS1 to “1”. The status of the Fuse High bits can now be
4. Set OE to “0”, BS2 to “0” and BS1 to “1”. The status of the Lock bits can now be read at
5. Set OE to “1”.
Figure 28-6. Mapping Between BS1, BS2 and the Fuse and Lock Bits During Read
The algorithm for reading the Signature bytes is as follows (refer to
page 202
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte (0x00 - 0x02).
3. Set OE to “0”, and BS to “0”. The selected Signature byte can now be read at DATA.
4. Set OE to “1”.
The algorithm for reading the Calibration byte is as follows (refer to
page 202
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte, 0x00.
3. Set OE to “0”, and BS1 to “1”. The Calibration byte can now be read at DATA.
4. Set OE to “1”.
read at DATA (“0” means programmed).
read at DATA (“0” means programmed).
DATA (“0” means programmed).
for details on Command and Address loading):
for details on Command and Address loading):
for details on Command loading):
Fuse High Byte
Fuse Low Byte
Lock Bits
0
BS2
BS2
0
1
0
1
BS1
0
1
”Programming the Flash” on
”Programming the Flash” on
”Programming the Flash”
DATA
ATmega406
207

Related parts for ATmega406