ATmega406 Atmel Corporation, ATmega406 Datasheet - Page 154

no-image

ATmega406

Manufacturer Part Number
ATmega406
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATmega406

Flash (kbytes)
40 Kbytes
Pin Count
48
Max. Operating Frequency
1 MHz
Cpu
8-bit AVR
# Of Touch Channels
8
Hardware Qtouch Acquisition
No
Max I/o Pins
18
Ext Interrupts
4
Usb Speed
No
Usb Interface
No
Twi (i2c)
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
11
Adc Resolution (bits)
12
Adc Speed (ksps)
1.9
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
2
Eeprom (bytes)
512
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-30 to 85
I/o Supply Class
4.0 to 25
Operating Voltage (vcc)
4.0 to 25
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
3
Pwm Channels
2
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATmega406-1AAU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATmega406-1AAU
Manufacturer:
AT
Quantity:
20 000
25.8.1
154
ATmega406
Master Transmitter Mode
In
bers in the circles show the status code held in TWSR, with the prescaler bits masked to zero. At
these points, actions must be taken by the application to continue or complete the TWI transfer.
The TWI transfer is suspended until the TWINT flag is cleared by software.
When the TWINT flag is set, the status code in TWSR is used to determine the appropriate soft-
ware action. For each status code, the required software action and details of the following serial
transfer are given in
these tables.
In the Master Transmitter mode, a number of data bytes are transmitted to a slave receiver (see
Figure
mat of the following address packet determines whether Master Transmitter or Master Receiver
mode is to be entered. If SLA+W is transmitted, MT mode is entered, if SLA+R is transmitted,
MR mode is entered. All the status codes mentioned in this section assume that the prescaler
bits are zero or are masked to zero.
Figure 25-12. Data Transfer in Master Transmitter Mode
Figure 25-13
SDA
SCL
S:
Rs:
R:
W:
A:
A:
Data:
P:
SLA:
25-12). In order to enter a Master mode, a START condition must be transmitted. The for-
TRANSMITTER
Device 1
MASTER
to
Figure
Table 25-3
25-19, circles are used to indicate that the TWINT flag is set. The num-
Device 2
RECEIVER
SLAVE
START condition
REPEATED START condition
Read bit (high level at SDA)
Write bit (low level at SDA)
Acknowledge bit (low level at SDA)
Not acknowledge bit (high level at SDA)
8-bit data byte
STOP condition
Slave Address
to
Table
Device 3
25-6. Note that the prescaler bits are masked to zero in
........
Device n
V
BUS
R1
R2
2548E–AVR–07/06

Related parts for ATmega406