DS3170+ Maxim Integrated Products, DS3170+ Datasheet - Page 147

IC TXRX DS3/E3 100-CSBGA

DS3170+

Manufacturer Part Number
DS3170+
Description
IC TXRX DS3/E3 100-CSBGA
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS3170+

Function
Single-Chip Transceiver
Interface
DS3, E3
Number Of Circuits
1
Voltage - Supply
3.135 V ~ 3.465 V
Current - Supply
120mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-LBGA
Includes
DS3 Framers, E3 Framers, HDLC Controller, On-Chip BERTs
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
TEIR[2:0]
000
001
010
011
100
101
110
111
Bit 2: Bit Error Insertion Enable (BEI) – When 0, single bit error insertion is disabled. When 1, single bit error
insertion is enabled.
Bit 1: Transmit Single Error Insert (TSEI) – This bit causes a bit error to be inserted in the transmit data stream if
manual error insertion is disabled (MEIMS = 0) and single bit error insertion is enabled. A 0 to 1 transition causes a
single bit error to be inserted. For a second bit error to be inserted, this bit must be set to 0, and back to 1. Note: If
MEIMS is low, and this bit transitions more than once between error insertion opportunities, only one error will be
inserted.
Bit 0: Manual Error Insert Mode Select (MEIMS) – When 0, error insertion is initiated by the TSEI register bit.
When 1, error insertion is initiated by the transmit manual error insertion signal (TMEI). Note: If TMEI or TSEI is
one, changing the state of this bit may cause a bit error to be inserted.
Register Name:
Register Description:
Register Address:
Bit #
Name
Bit #
Name
Bit 3: Performance Monitoring Update Status (PMS) – This bit indicates the status of the receive performance
monitoring register (counters) update. This bit will transition from low to high when the update is completed. PMS
will be forced low when the LPMU bit (PMUM = 0) or the global or port PMU bit (PMUM=1) goes low.
Bit 1: Bit Error Count (BEC) – When 0, the bit error count is zero. When 1, the bit error count is one or more.
This bit is cleared when the user updates the BERT counters via the PMU bit (BERT.CR).
Bit 0: Out Of Synchronization (OOS) – When 0, the receive pattern generator is synchronized to the incoming
pattern. When 1, the receive pattern generator is not synchronized to the incoming pattern.
15
--
--
7
Error Rate
Disabled
1*10
1*10
1*10
1*10
1*10
1*10
1*10
-1
-2
-3
-4
-5
-6
-7
14
--
--
6
BERT.SR
BERT Status Register
06Ch
13
--
--
5
147 of 230
12
--
--
4
PMS
11
--
3
DS3170 DS3/E3 Single-Chip Transceiver
10
--
--
2
BEC
--
9
1
OOS
--
8
0

Related parts for DS3170+