PI7C7300DNAE Pericom Semiconductor, PI7C7300DNAE Datasheet - Page 53

IC PCI-PCI BRIDGE 3PORT 272-BGA

PI7C7300DNAE

Manufacturer Part Number
PI7C7300DNAE
Description
IC PCI-PCI BRIDGE 3PORT 272-BGA
Manufacturer
Pericom Semiconductor
Datasheet

Specifications of PI7C7300DNAE

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
272-PBGA
Mounting Type
Surface Mount
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3 V to 3.6 V
Supply Current (max)
660 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PI7C7300DNAE
Manufacturer:
Pericom
Quantity:
135
Part Number:
PI7C7300DNAE
Manufacturer:
MAX
Quantity:
5 510
Part Number:
PI7C7300DNAE
Manufacturer:
Pericom
Quantity:
10 000
7.2
7.2.1
7.2.2
Pericom Semiconductor
When PI7C7300D detects an address parity error on the secondary interface, the
following events occur:
DATA PARITY ERRORS
When forwarding transactions, PI7C7300D attempts to pass the data parity condition
from one interface to the other unchanged, whenever possible, to allow the master and
target devices to handle the error condition.
The following sections describe, for each type of transaction, the sequence of events that
occurs when a parity error is detected and the way in which the parity condition is
forwarded across PI7C7300D.
CONFIGURATION WRITE TRANSACTIONS TO
CONFIGURATION SPACE
When PI7C7300D detects a data parity error during a Type 0 configuration write
transaction to PI7C7300D configuration space, the following events occur:
READ TRANSACTIONS
When PI7C7300D detects a parity error during a read transaction, the target drives data
and data parity, and the initiator checks parity and conditionally asserts PERR#.
For downstream transactions, when PI7C7300D detects a read data parity error on the
secondary bus, the following events occur:
-
-
If the parity error response bit is set in the bridge control register, PI7C7300D does
not claim the transaction with S1_DEVSEL# or S2_DEVSEL#; this may allow the
transaction to terminate in a master abort. If parity error response bit is not set,
PI7C7300D proceeds normally and accepts transaction if it is directed to or across
PI7C7300D.
PI7C7300D sets the detected parity error bit in the secondary status register.
PI7C7300D asserts P_SERR# and sets signaled system error bit in status register, if
both of the following conditions are met:
-
-
If the parity error response bit is set in the command register, PI7C7300D asserts
P_TRDY# and writes the data to the configuration register. PI7C7300D also asserts
P_PERR#. If the parity error response bit is not set, PI7C7300D does not assert
P_PERR#.
PI7C7300D sets the detected parity error bit in the status register, regardless of the
state of the parity error response bit.
The SERR# enable bit is set in the command register.
The parity error response bit is set in the command register.
The SERR# enable bit is set in the command register.