AD9929BBCZ Analog Devices Inc, AD9929BBCZ Datasheet - Page 56

IC CCD SIGNAL PROCESSOR 64-BGA

AD9929BBCZ

Manufacturer Part Number
AD9929BBCZ
Description
IC CCD SIGNAL PROCESSOR 64-BGA
Manufacturer
Analog Devices Inc
Type
CCD Signal Processor, 12-Bitr
Datasheet

Specifications of AD9929BBCZ

Input Type
Logic
Output Type
Logic
Interface
3-Wire Serial
Mounting Type
Surface Mount
Package / Case
64-CSPBGA
Analog Front End Type
CCD
Analog Front End Category
Video
Interface Type
Serial (3-Wire)
Input Voltage Range
0.5V
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (typ)
3V
Operating Supply Voltage (max)
3.6V
Resolution
12b
Number Of Adc's
1
Power Supply Type
Analog/Digital
Operating Temp Range
-20C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
64
Package Type
CSPBGA
Number Of Channels
1
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9929BBCZ
Manufacturer:
ADI
Quantity:
531
AD9929
STANDBY MODE OPERATION
Recommended Standby Mode Sequence
When the AD9929 is going into standby operation, the follow-
ing sequence is recommended (refer to Figure 67 for each step).
1.
2.
(INTERNAL SIGNAL)
Program OUTCONT_REG (Address 0x05) = 0. This
asserts the internal OUTCONT signal low, causing all
digital outputs to become disabled.
Program registers AFESTBY (Address 0x05) = 0 and
DIGSTBY (Address 0x05) = 0. The AD9929 is now in
standby operation.
(REGISTER)
(REGISTER)
SUPPLIES
OUTCONT
(OUTPUT)
(OUTPUT)
OUTPUTS
AFESTBY
DIGSTBY
DIGITAL
WRITES
DCLK2
AD9929
(INPUT)
SERIAL
DCLK1
AND
CLI
HD
VD
1
NOTES
1
2
DCLK2 WILL BE OUTPUT ON THE FD/DCLK2 PIN 16 PROVIDING REGISTER DCLK2SEL (ADDRESS 0xD5) = 1.
IT TAKES 11 CLI CLOCKS FROM WHEN OCONT GOES HIGH UNTIL VD, HD, AND DIGITAL OUTPUT DATA IS VALID.
1
2
Figure 67. Recommended Standby Sequence
3
Rev. A | Page 56 of 64
H1, VSUB
H2, RG, MSHUT, STROBE, FD
5
3.
4.
5.
6.
When ready to come out of standby operation, program
register DIGSTBY (Address 0x05) = 1 and register
AFESTBY (Address 0x05) = 1.
Program necessary control registers.
Program control register MODE (Address 0x0A) = 0. This
selects Mode_A operation.
Program register OUTCONT_REG (Address 0x05) = 1.
This asserts the internal OUTCONT signal high, causing
all digital outputs to become active.
6
t
DELAY
2