ADE7166ASTZF8 Analog Devices Inc, ADE7166ASTZF8 Datasheet - Page 28

IC ENERGY METER 1PHASE 64LQFP

ADE7166ASTZF8

Manufacturer Part Number
ADE7166ASTZF8
Description
IC ENERGY METER 1PHASE 64LQFP
Manufacturer
Analog Devices Inc
Datasheets

Specifications of ADE7166ASTZF8

Applications
Energy Measurement
Core Processor
8052
Program Memory Type
FLASH (8 kB)
Controller Series
ADE71xx
Ram Size
512 x 8
Interface
I²C, SPI, UART
Number Of I /o
20
Voltage - Supply
3.135 V ~ 3.465 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
64-LQFP
Ic Function
Single Phase Energy Measurement IC
Supply Voltage Range
3.13V To 3.46V, 2.4V To 3.7V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
LQFP
No. Of Pins
64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7166ASTZF8
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
ADE7166ASTZF8-RL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
ADE7566/ADE7569/ADE7166/ADE7169
POWER SUPPLY ARCHITECTURE
Each ADE7566/ADE7569/ADE7166/ADE7169 has two power
supply inputs, V
power supply at V
secondary power supply, with a maximum of 3.7 V can be
connected to the V
ADE7166/ADE7169 connect V
to derive power for the ADE7566/ADE7569/ ADE7166/ADE7169
circuitry. The V
internal power supply (V
current of 6 mA. This pin can also be used to power a limited
number of peripheral components. The 2.5 V analog supply (V
and the 2.5 V supply for the core logic (V
chip linear regulators from V
supply architecture of ADE7566/ADE7569/ADE7166/ADE7169.
The ADE7566/ADE7569/ADE7166/ADE7169 provide
automatic battery switchover between V
the voltage level detected at V
BCTRL input can be used to trigger a battery switchover. The
conditions for switching V
V
input pin that can be connected to a 0 V to 3.3 V dc signal. This
input is intended for power supply supervisory purposes and
does not provide power to the ADE7566/ADE7569/ADE7166/
ADE7169 circuitry (see the
BATTERY SWITCHOVER
The ADE7566/ADE7569/ADE7166/ADE7169 monitor V
and V
configured based on the status of V
Battery switchover is enabled by default. Setting Bit 1 in the
Battery Switchover Configuration SFR (BATPR, 0xF5) disables
battery switchover so that V
(see
Peripheral Configuration SFR (PERIPH, 0xF4), which is
described in Table 19. Bit 6 is set when V
V
DD
BCTRL
DD
are described in the
Table 18). The source of V
and cleared when V
DCIN
V
. Automatic battery switchover from V
DCIN
POWER SUPPLY
MANAGEMENT
SCRATCHPAD
V
SWOUT
DD
DD
Figure 31. Power Supply Architecture
DD
TEMPERATURE ADC
and V
BAT
V
for full operation. A battery backup, or
BAT
output pin reflects the voltage at the
input. Internally, the ADE7566/ADE7569/
BAT
SWOUT
Battery Switchover section. V
V
SWOUT
ADC
SW
SWOUT
, and require only a single 3.3 V
SWOUT
Battery Switchover section).
DD
ADC
LCD
V
DD
) and has a maximum output
DD
SWOUT
is connected to V
SWOUT
is always connected to V
from V
.
or V
or V
Figure 31 shows the power
DD
is indicated by Bit 6 in the
BAT
DCIN
LDO
LDO
RTC
, V
DD
to V
DD
DCIN
. Additionally, the
SWOUT
INTD
to V
and V
V
V
3.3V
SWOUT
INTD
, or the BCTRL pin.
INTA
) are derived by on-
is connected to
BAT
DD
BAT
, which is used
BAT
and back to
to V
.
2.5V
SPI/I
UART
MCU
ADE
based on
DCIN
BAT
2
DD
SWOUT
C
, V
can be
is an
INTA
BAT
Rev. A | Page 28 of 144
,
)
The battery switchover functionality provided by the
ADE7566/ADE7569/ADE7166/ADE7169 allows a seamless
transition from V
option ensures a stable power supply to the ADE7566/
ADE7569/ADE7166/ADE7169, as long as the external battery
voltage is above 2.75 V. It allows continuous code execution
even while the internal power supply is switching from V
V
available when V
Power supply monitor (PSM) interrupts can be enabled to
indicate when battery switchover occurs and when the V
power supply is restored (see the Power Supply Monitor
Interrupt (PSM) section.)
V
The following three events switch the internal power supply
(V
Switching from V
To switch V
that are enabled to force battery switchover must be false:
DD
BAT
SWOUT
to V
V
from V
BATPRG[1:0] bits in the Battery Switchover Configuration
SFR (BATPR, 0xF5) = 0b01. Setting these bits disables
switchover based on V
disabled by default.
V
from V
the BATPR SRF are cleared.
Falling edge on BCTRL. When the battery control pin,
BCTRL, goes low, V
external switchover signal can trigger a switchover to V
at any time. Setting bits INT1PRG[4:2] to 0bx01 in the
Interrupt Pins Configuration SFR (INTPR, 0xFF) enables
the battery control pin (see Table 16).
V
condition is enabled, V
remains above 1.2 V and V
V
V
BCTRL enabled. V
is high, and the first or second bullet point is satisfied.
and back. Note that the energy metering ADCs are not
DCIN
DD
DCIN
DD
DD
) from V
BAT
< 2.75 V. When V
< 2.75 V enabled. V
remains above 2.75 V.
< 1.2 V. When V
< 1.2 V and V
DD
DD
SWOUT
to V
to V
DD
BAT
from V
DD
BAT
BAT
to V
BAT
to V
is being used for V
. This event is enabled when the
. This event is enabled when BATPRG[1:0] in
to V
BAT
SWOUT
DD
BAT
SWOUT
BAT
:
DCIN
DD
DD
DCIN
. An automatic battery switchover
< 2.75 V enabled. If the low V
SWOUT
to V
SWOUT
switches back to V
falls below 2.75 V, V
falls below 1.2 V, V
switches from V
. Battery switchover on low V
DD
DD
switches to V
remains above 2.75 V.
, all of the following events
switches back to V
SWOUT
.
DD
DD
DD
SWOUT
to V
after V
SWOUT
after BCTRL
DD
switches
BAT
switches
after
. This
DCIN
DD
DD
DCIN
DCIN
to
BAT
is

Related parts for ADE7166ASTZF8