JS28F512P33BFD Micron Technology Inc, JS28F512P33BFD Datasheet - Page 73

no-image

JS28F512P33BFD

Manufacturer Part Number
JS28F512P33BFD
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of JS28F512P33BFD

Cell Type
NOR
Density
512Mb
Access Time (max)
105/17ns
Interface Type
Parallel/Serial
Boot Type
Bottom
Address Bus
25b
Operating Supply Voltage (typ)
2.5/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
8.5 to 9.5V
Sync/async
Async/Sync
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.3V
Operating Supply Voltage (max)
3.6V
Word Size
16b
Number Of Words
32M
Supply Current
31mA
Mounting
Surface Mount
Pin Count
56
Lead Free Status / RoHS Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JS28F512P33BFD
Manufacturer:
FREESCALE
Quantity:
1 001
Part Number:
JS28F512P33BFD
Manufacturer:
MICRON
Quantity:
20 000
P33-65nm
Figure 31: Program Suspend/Resume Flowchart
Datasheet
75
Yes
Read Status Register
Read Status Register
Write Confirm D0h
Another Buffered
Issue Write to Buffer
Is WSM Ready ?
Write Word Count
Write Buffer Data
Program Complete
Command E8h
Block Address
Check if Desired
Programming?
Supports Buffer
Target Address
Block Address
Block Address
Set Timeout or
Block Address
Loop Counter
Start Address
Full Status
X = N?
Get Next
SR. 7 =?
(note 7)
Writes ?
SR. 7 =
Device
X = 0
Start
1
1 = Yes
Yes
Yes
No
No
No
Write Buffer Data
Abort Bufferred
Buffered Program
Use Single Word
Block Address
Write to another
Block Address
Programming
Program?
Timeout
or Count
Expired ?
No
X = X + 1
Aborted
Suspend
Program
No
Yes
No
Yes
Yes
Suspend
Program
Loop
Notes:
1. Word count values on DQ
register. Count ranges for this device are N=0000h to 01FFh.
2. The device outputs the Status Register when read.
3. Write Buffer contents will be programmed at the device start
address or destination flash address .
4. Align the start address on a Write Buffer boundary for
maximum programming performance (i.e., A
address =0).
5. The device aborts the Buffered Program command if the
current address is outside the original block address .
6. The Status register indicates an “improper command
Sequence” if the Buffered Program command is aborted.
Follow this with a Clear Status Register command .
7. The device defaults to output SR data after the Buffered
Programming Setup Command (E8h) is issued . CE# or OE#
must be be toggled to update Status Register . Don’t issue the
Read SR command (70h), which would be interpreted by the
internal state machine as Buffer Word Count.
8. Full status check can be done after all erase and write
sequences complete . Write FFh after the last operation to
reset the device to read array mode.
( Notes 1, 2)
( Notes 3, 4)
( Notes 5, 6)
Operation
Standby
Standby
(Note 7)
Read
Write
Write
Write
Write
Write
Bus
Read
Command
Confirm
Program
Write to
Buffer
.
0
-DQ
SR. 7 = Valid
Addr = Address within buffer range
Status register Data
CE # and OE# low updates SR
1 = Device WSM is Busy
0 = Device WSM is Ready
1 = WSM Ready
0 = WSM Busy
N = 0 corresponds to count = 1
Data = E8H
Addr = Block Address
Addr = Block Address
Check SR .7
Data = N- 1 = Word Count
Addr = Block Address
Data = Write Buffer Data
Data = Write Buffer Data
Addr = Block Address
Data = D0H
Addr = Block Address
Addr = Block Address
Check SR .7
15
are loaded into the Count
Comments
.
9
-A
1
of the start
Order Number:208043-05
.
Apr 2010