Specifications of CS1W-CN625

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
1-5
1-5-2
Relay PLC Communications Settings
1-26
Display format:
Description:
Contents
Display item
Offline Displays
Relay PLC Communications Settings
Online Connection
Information Window
Window Descriptions
Main Window
TargetComponent
Display in Online
Connection
Information
Online
[relay PLC’s CPU Unit model] Net (Network Address) Node (Node Address)
The following network
types will be displayed for
the connection to the
relay PLC.
TargetPLC
Window
Offline, Network Type, COM Port No., Baud Rate, Parity, Data Bits, Stop Bits
*1 To connect the computer (CX-Integrator) directly to a CompoWay/F Slave through a serial
Network Type
connection, select CompoWay/F Device as the PLC model.
Offline displayed.
or
1) Online connection to
the relay PLC
2) Status Online
connection to the
target PLC
3) A connection to one
of the Communications
Units/ports at the
target PLC (Access is
possible.)
Level
COM port on
computer
COM Port
No.
Network Type
COM Port No., Baud Rate, Parity, Data
Bits, Stop Bits
Right-click the
communications settings
for the relay PLC and
select Auto Online or
Work Online.
The operation is the same
as above when the relay
PLC is the target PLC.
If the target PLC is
different from the relay
PLC, upload the
communications
configuration, right-click
the target PLC, and select
Connect to this PLC.
Right-click the
Communications Unit/port
and select Connect.
(Displayed
only for
Toolbus or
SYSMAC
Baud Rate
Operation
(Displayed
only for
SYSMAC
WAY)
Relay PLC’s CPU Unit
Relay PLC’s FINS destination network address
Relay PLC’s FINS destination node
Parity
Remember that this icon
indicates that the online
connection is to the relay
PLC.
An online connection to the
target PLC is made after
connecting online to the relay
PLC, as described above.
The following operations are
possible for the CPU Unit at
the target PLC.
I/O tables: Creating, editing,
and transferring I/O tables
Error log: Displaying current
errors and error logs
Mode setting: Changing the
operating mode
Only one Communications
Unit/port can be accessed at
any one time.
Communications
configurations can be
uploaded only for a
Communications Unit/port in
this status.
Note: Access is possible to a
Communications Unit/port
only when it is connected.
Access is not possible when
disconnected.
(Displayed
only for
SYSMAC
WAY)
Data Bits
Remarks
(Displayed
only for
SYSMAC
WAY)
Stop Bits
Relay PLC
communications
settings