CS1W-CN625 Omron, CS1W-CN625 Datasheet - Page 28

no-image

CS1W-CN625

Manufacturer Part Number
CS1W-CN625
Description
CBL,PROG
Manufacturer
Omron
Datasheet

Specifications of CS1W-CN625

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
1-2
1-2-1
1-10
Communications
monitoring functions
Setting functions
Verification functions
Operations
Item
Specifications
CX-Integrator Specifications
Ethernet
Controller Link
SYSMAC LINK
DeviceNet
CompoWay/F
NT Link
Ethernet
Controller Link
SYSMAC LINK
DeviceNet
CompoWay/F
NT Link
FINS networks, such
as Ethernet, Controller
Link, SYSMAC LINK,
and DeviceNet
Verifying communications/network configurations
Verifying component parameters
The following operations are possible for the CPU Unit at the target PLC.
Creating, editing, and transferring I/O tables
Displaying current errors and error logs
Changing the operating mode
Transferring or verifying a manually set data link table
Transferring or verifying a routing table (FINS local routing table)
Node information for FINS communications (CPU Unit model, Ethernet
Unit mode, node address, and network address)
Information on nodes participating in the Controller Link network (CPU
Unit model, Controller Link Unit mode, node address, and network
address)
The following functions are also possible if the Controller Link Network
Diagnostic Tool is started.
Configuration node diagnosis (network participation status, current
Controller Link Unit errors, current CPU Unit errors, and differences from
node files), setting diagnosis (e.g., DM Area parameter setting
consistency), line disconnection information diagnosis, transmission
status diagnosis, node status (displaying current error status and error
log), error log collection, and node file editing (node names, connection
order, and Repeater Units)
Information on nodes participating in the SYSMAC LINK network (CPU
Unit model, Controller Link Unit mode, node address, and network
address)
Information on nodes connected to DeviceNet for which EDS files are
installed on the computer (DeviceNet Unit model, slave model,
master/slave node addresses)
Information on nodes connected to a serial port in serial gateway mode or
protocol macro mode for which CPS files are installed on the computer
(CompoWay/F SLAVE model and CompoWay/F node address).
Note: CS/CJ-series CPU Units with unit version 3.0 or later or Serial
Information on nodes connected to 1:N NT Links (NS-series PT model
and NT Link unit number)
Note: Automatic detection of NS-series PTs connected serially to a
Ethernet Unit settings (CPU Bus Unit System Settings)
User-set data link tables
Controller Link and SYSMAC LINK Unit settings (in allocated DM Area
words), including automatically set data link parameters (transferred to
the startup node set as the target PLC)
DeviceNet Unit master parameters (remote I/O allocations, connection
settings, device information check, communications cycle time, etc.)
Slave parameters
CompoWay/F slave parameters (except for Temperature Controllers)
Note: Parameters for CompoWay/F-compatible Temperature Controllers
PLC serial port communications settings (CPU Unit: part of PLC Setup,
Serial Communications Boards/Units: allocated DM Area words)
None
Routing tables (FINS local routing tables and FINS network routing
tables)
Note: The FINS local routing table is transferred to the target PLC.
Communications Boards/Units with unit version 1.2 or later must be
used.
CS/CJ-series PLC is also possible. (The NT Link Automatic Setting
Function automatically changes the setting of the PLC’s serial port
to match those of the NS-series PT.)
are set using the CX-Thermo, started as an application.