CS1W-CN625 Omron, CS1W-CN625 Datasheet - Page 26

no-image

CS1W-CN625

Manufacturer Part Number
CS1W-CN625
Description
CBL,PROG
Manufacturer
Omron
Datasheet

Specifications of CS1W-CN625

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
1-2
1-2-1
1-2
1-2-1
Model
Setup media
Applicable
computers
(with
FinsGateway)
PLCs that can be used
as relay PLC for online
connections
Note: A relay PLC is the
PLC to which the
CX-Integrator is
connected online.
1-8
Connecting to the
Relay PLC
Item
Specifications
CX-Integrator Specifications
Specifications
CX-Integrator Specifications
Computer IBM PC/AT or compatible
CPU
OS
Memory
Hard disk
drive
Monitor
CD-ROM
drive
Communi
cations
port
Provided in the CX-One FA Integrated Tool Package (CXONE-AL@@C-E).
CD-ROM
Pentium 133 MHz or better for Windows 98 SE or NT 4.0 with service pack 6a
Microsoft Windows 98 SE, Me, 2000, or XP
Microsoft Windows NT version 4.0 service pack 6a
Note: CX-Integrator cannot be used with Windows 95.
64 MB min. for Windows 98 SE or NT 4.0 with service pack 6a
100 MB min. of available space
SVGA, 800 x 600 pixels or better
Note: Use the small font size.
At least one required.
At least one RS-232C or USB port (See note.)
Note: The USB port on a computer can be connected to if the CJ1W-CIF31 USB-Serial Conversion
CS Series
CJ Series
Note: To connect the computer running CX-Integrator directly as a CompoWay/F slave, set
Either of the following can be used.
Serial
communications
FINS network
communications
Series
Cable is used. (The driver software included with the CJ1W-CIF31 must be installed on the
computer.)
the Device type to CompoWay/F Device.
CS1H
CS1G/CJ1G CS1G-CPU45/44/43/42(-V1)
CS1G-H
CS1H-H
CS1D-H
CS1D-S
CS1G/CJ1G CJ1G-CPU45/44
CJ1M
CJ1G-H
CJ1H-H
Device type
(See note.)
Direction connection is possible to any of the following serial ports on a
CS/CJ-series PLC.
• CPU Unit peripheral port (Toolbus or Host Link)
• CPU Unit RS-232C port (Toolbus or Host Link)
• Serial Communications Board or Serial Communications Unit RS-232C
Note: Automatic online connection is possible for serial
Direction connection is possible through any of the following networks on
a CS/CJ-series PLC.
• Ethernet (Ethernet, Ethernet FINS/TCP, or FinsGateway)
• Controller Link (Controller Link or FinsGateway)
• SYSMAC LINK (SYSMAC LINK or FinsGateway)
port or RS-422A/485 port (Host Link)
CS1H-CPU67/66/65/64/63(-V1)
CS1G-CPU45H/44H/43H/42H
CS1H-CPU67H/66H/65H/64H/63H
CS1D-CPU67H/65H
Note: When using a pre-Ver. 1.1 CS1D-H CPU Unit, use it as if it
CS1D-CPU67S/65S/44S/42S
CJ1M-CPU23/22/21/13/12/11
CJ1G- CPU45H/44H/43H/42H
CJ1H-CPU67H/66H/65H
communications ports. (The user does not have to set the
computer communications settings.) The communications
settings will be automatically set to those of the PLC.
Connection is possible to a serial port on the CPU Unit, a
Serial Communications Board, or a Serial Communications
Unit. For PLC serial ports, however, only the Toolbus or Host
Link serial communications modes can be used and the baud
rate must be 9600, 19200, 38400, or 115200 bits/s.
were a CS1H-H CPU Unit.
Specification
CPU Unit model

Related parts for CS1W-CN625