Specifications of AT91SAM7SE256B-AUR

Core Processor
ARM7
Core Size
16/32-Bit
Speed
55MHz
Connectivity
EBI/EMI, I²C, SPI, SSC, UART/USART, USB
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
88
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Processor Series
SAM7SE256
Core
ARM7TDMI
Data Bus Width
32 bit
Data Ram Size
32 KB
Interface Type
SPI, USB
Maximum Clock Frequency
48 MHz
Number Of Programmable I/os
88
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Operating Temperature Range
- 40 C to + 85 C
Processor To Be Evaluated
AT91SAM7SE256B
Supply Current (max)
60 uA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7SE256B-AUR
Manufacturer:
Atmel
Quantity:
10 000
43.2.1.7
43.2.1.8
43.2.1.9
43.2.1.10
43.2.1.11
6222F–ATARM–14-Jan-11
ADC: GOVRE Bit is not Set when Disabling a Channel
ADC: EOC Set although Channel Disabled
ADC: Spurious Clear of EOC Flag
ADC: Sleep Mode
ADC: OVRE Flag Behavior
GOVRE should be set but is not.
None
When disabling channel "y" at the same instant as an end of conversion on channel "x", EOC[x]
and DRDY being already active, GOVRE does not rise.
Note:
None
When the OVRE flag (on channel i) has been set but the related EOC status (of channel i) has
been cleared (by a read of CDRi or LCDR), reading the Status register at the same instant as an
end of conversion (causing the set of EOC status on channel i), does not lead to a reset of the
OVRE flag (on channel i) as expected.
None
If a channel is disabled while a conversion is running and if a read of CDR is performed at the
same time as an end of conversion of any channel occurs, the EOC of the channel with the con-
version running may rise (whereas it has been disabled).
Do not take into account the EOC of a disabled channel
If "x" and "y" are two successively converted channels and "z" is yet another enabled channel
("z" being neither "x" nor "y"), reading CDR on channel "z" at the same instant as an end of con-
version on channel "y" automatically clears EOC[x] instead of EOC[z].
None.
If Sleep mode is activated while there is no activity (no conversion is being performed), it will
take effect only after a conversion occurs.
To activate sleep mode as soon as possible, it is recommended to write successively, ADC
Mode Register (SLEEP) then ADC Control Register (START bit field); to start an analog-to-digi-
tal conversion, in order put ADC into sleep mode at the end of this conversion.
• DRDY already active,
• GOVRE inactive,
• previous data stored in LCDR being neither data from channel "y", nor data from channel "x".
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround:
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
OVRE[x] rises as expected.