HD64F2134FA20 Renesas Electronics America, HD64F2134FA20 Datasheet - Page 548

no-image

HD64F2134FA20

Manufacturer Part Number
HD64F2134FA20
Description
IC H8S MCU FLASH 128K 80QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2100r
Datasheets

Specifications of HD64F2134FA20

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
IrDA, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
58
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
80-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2134FA20
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F2134FA20V
Manufacturer:
RENESAS
Quantity:
201
Section 16 I
16.3.4
In slave receive mode, the master device outputs the transmit clock and transmit data, and the
slave device returns an acknowledge signal. The reception procedure and operations in slave
receive mode are described below.
[1] Set the ICE bit in ICCR to 1. Set the MLS bit in ICMR and the MST and TRS bits in ICCR
[2] When the start condition output by the master device is detected, the BBSY flag in ICCR is set
[3] When the slave address matches in the first frame following the start condition, the device
[4] At the 9th clock pulse of the receive frame, the slave device drives SDA low and returns an
[5] Read ICDR and clear the IRIC flag in ICCR to 0. The RDRF flag is cleared to 0.
Rev. 4.00 Jun 06, 2006 page 492 of 1004
REJ09B0301-0400
according to the operating mode.
to 1.
operates as the slave device specified by the master device. If the 8th data bit (R/W) is 0, the
TRS bit in ICCR remains cleared to 0, and slave receive operation is performed.
acknowledge signal. At the same time, the IRIC flag in ICCR is set to 1. If the IEIC bit in
ICCR has been set to 1, an interrupt request is sent to the CPU. If the RDRF internal flag has
been cleared to 0, it is set to 1, and the receive operation continues. If the RDRF internal flag
has been set to 1, the slave device drives SCL low from the fall of the receive clock until data
is read into ICDR.
Receive operations can be performed continuously by repeating steps [4] and [5]. When SDA
is changed from low to high when SCL is high, and the stop condition is detected, the BBSY
flag in ICCR is cleared to 0.
Slave Receive Operation
2
C Bus Interface [H8S/2138 Group Option]

Related parts for HD64F2134FA20