UPD78F0533AGB-GAH-AX Renesas Electronics America, UPD78F0533AGB-GAH-AX Datasheet - Page 385

no-image

UPD78F0533AGB-GAH-AX

Manufacturer Part Number
UPD78F0533AGB-GAH-AX
Description
MCU 8BIT 64-LQFP
Manufacturer
Renesas Electronics America
Series
78K0/Kx2r
Datasheet

Specifications of UPD78F0533AGB-GAH-AX

Core Processor
78K/0
Core Size
8-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
55
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F0533AGB-GAH-AX
Manufacturer:
RENESAS
Quantity:
460
Part Number:
UPD78F0533AGB-GAH-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
78K0/Kx2
R01UH0008EJ0401 Rev.4.01
Jul 15, 2010
<10> By performing the procedures above, an arbitrary carrier clock is obtained. To stop the count operation, clear
TMHE1 to 0.
If the setting value of the CMP01 register is N, the setting value of the CMP11 register is M, and the count clock
frequency is f
• Carrier clock output cycle = (N + M + 2)/f
• Duty = High-level width/carrier clock output width = (M + 1)/(N + M + 2)
Cautions 1. Be sure to set the CMP11 register when starting the timer count operation (TMHE1 = 1)
Remarks 1. For the setting of the output pin, see 9.3 (3) Port mode register 1 (PM1).
2. For how to enable the INTTMH1 signal interrupt, see CHAPTER 20 INTERRUPT FUNCTIONS.
2. Set so that the count clock frequency of TMH1 becomes more than 6 times the count clock
3. Set the values of the CMP01 and CMP11 registers in a range of 01H to FFH.
4. The set value of the CMP11 register can be changed while the timer counter is operating.
5. Be sure to set the RMC1 bit before the count operation is started.
CNT
after the timer count operation was stopped (TMHE1 = 0) (be sure to set again even if
setting the same value to the CMP11 register).
frequency of TM51.
However, it takes the duration of three operating clocks (signal selected by the CKS12 to
CKS10 bits of the TMHMD1 register) since the value of the CMP11 register has been
changed until the value is transferred to the register.
, the carrier clock output cycle and duty are as follows.
CNT
CHAPTER 9 8-BIT TIMERS H0 AND H1
385

Related parts for UPD78F0533AGB-GAH-AX