AT32UC3B1256-AUR Atmel, AT32UC3B1256-AUR Datasheet - Page 499

MCU AVR32 256K FLASH 48-TQFP

AT32UC3B1256-AUR

Manufacturer Part Number
AT32UC3B1256-AUR
Description
MCU AVR32 256K FLASH 48-TQFP
Manufacturer
Atmel
Series
AVR®32 UC3r
Datasheet

Specifications of AT32UC3B1256-AUR

Package / Case
48-TQFP, 48-VQFP
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Operating Temperature
-40°C ~ 85°C
Speed
60MHz
Number Of I /o
28
Core Processor
AVR
Program Memory Type
FLASH
Ram Size
32K x 8
Program Memory Size
256KB (256K x 8)
Data Converters
A/D 6x10b
Oscillator Type
Internal
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Connectivity
I²C, IrDA, SPI, SSC, UART/USART, USB
Core Size
32-Bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3B1256-AUR
Manufacturer:
OMRON
Quantity:
12 000
Part Number:
AT32UC3B1256-AUR
Manufacturer:
Atmel
Quantity:
10 000
Company:
Part Number:
AT32UC3B1256-AUR
Quantity:
936
Figure 23-13. WAVSEL = 3 With Trigger
23.6.3.6
23.6.3.7
32059J–12/2010
Waveform Examples
External event/trigger conditions
Output controller
0xFFFF
Counter Value
RB
RA
RC
TIOB
TIOA
An external event can be programmed to be detected on one of the clock sources (XC0, XC1,
XC2) or TIOB. The external event selected can then be used as a trigger.
The External Event Selection field in CMRn (CMRn.EEVT) selects the external trigger. The
External Event Edge Selection field in CMRn (CMRn.EEVTEDG) defines the trigger edge for
each of the possible external triggers (rising, falling or both). If CMRn.EEVTEDG is written to
zero, no external event is defined.
If TIOB is defined as an external event signal (CMRn.EEVT = 0), TIOB is no longer used as an
output and the compare register B is not used to generate waveforms and subsequently no
IRQs. In this case the TC channel can only generate a waveform on TIOA.
When an external event is defined, it can be used as a trigger by writing a one to the
CMRn.ENETRG bit.
As in Capture mode, the SYNC signal and the software trigger are also available as triggers. RC
Compare can also be used as a trigger depending on the CMRn.WAVSEL field.
The output controller defines the output level changes on TIOA and TIOB following an event.
TIOB control is used only if TIOB is defined as output (not as an external event).
The following events control TIOA and TIOB:
• software trigger
• external event
• RC compare
RA compare controls TIOA and RB compare controls TIOB. Each of these events can be pro-
grammed to set, clear or toggle the output as defined in the following fields in CMRn:
Counter decremented by compare match
with RC
Counter decremented by trigger
Counter incremented by trigger
AT32UC3B
Time
499