HD6417708SF60V Renesas Electronics America, HD6417708SF60V Datasheet - Page 372

IC SUPERH MPU ROMLESS 208LQFP

HD6417708SF60V

Manufacturer Part Number
HD6417708SF60V
Description
IC SUPERH MPU ROMLESS 208LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417708SF60V

Core Processor
SH-2
Core Size
32-Bit
Speed
60MHz
Connectivity
EBI/EMI, SCI, SmartCard
Peripherals
POR, WDT
Number Of I /o
8
Program Memory Type
ROMless
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
208-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Ram Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417708SF60V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417708SF60V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Bit 6—Receive Data Register Full (RDRF): Indicates that SCRDR contains received data.
Bit 6: RDRF
0
1
Note: SCRDR and RDRF are not affected by detection of receive errors or by clearing of the RE
Bit 5—Overrun Error (ORER): Indicates that data reception aborted due to an overrun error.
Bit 5: ORER
0
1
352
bit to 0 in the serial control register. They retain their previous contents. If RDRF is still set
to 1 when reception of the next data ends, an overrun error (ORER) occurs and the receive
data is lost.
Description
SCRDR does not contain valid received data.
RDRF is cleared to 0 when the chip is reset or enters standby mode, software
reads RDRF after it has been set to 1, then writes 0 in RDRF, or data is read
from SCRDR.
SCRDR contains valid received data.
RDRF is set to 1 when serial data is received normally and transferred from
SCRSR to SCRDR.
Description
Receiving is in progress or has ended normally.
Clearing the RE bit to 0 in the serial control register does not affect the ORER bit,
which retains its previous value.
ORER is cleared to 0 when the chip is reset or enters standby mode or software
reads ORER after it has been set to 1, then writes 0 in ORER.
A receive overrun error occurred.
SCRDR continues to hold the data received before the overrun error, so
subsequent receive data is lost. Serial receiving cannot continue while ORER is
set to 1. In synchronous mode, serial transmitting is also disabled.
ORER is set to 1 if reception of the next serial data ends when RDRF is set to 1.
(Initial value)
(Initial value)

Related parts for HD6417708SF60V