HD64F38024DV Renesas Electronics America, HD64F38024DV Datasheet - Page 805

IC H8/SLP MCU FLASH 80QFP

HD64F38024DV

Manufacturer Part Number
HD64F38024DV
Description
IC H8/SLP MCU FLASH 80QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300L SLPr
Datasheets

Specifications of HD64F38024DV

Core Processor
H8/300L
Core Size
8-Bit
Speed
10MHz
Connectivity
SCI
Peripherals
LCD, PWM, WDT
Number Of I /o
51
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
80-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F38024DV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
11.7.1
The structured assembly function expands the structured assembly directives into predetermined
instructions and symbols, and performs no optimizations whatsoever. Thus the values that can be
specified as parameters to these directives are limited by the specifications of the instructions that
are generated. Furthermore, there are cases where inefficient code and/or unnecessary symbols
are generated.
1. Instruction Expansion
2. Symbol Expansion
The forms of structured assembly directives that involve testing condition codes may be
restricted by the statement that results from expansion of the directive.
Example:
.IF B (R0L<LT>#10)
.ENDI
The .IF directive is expanded to CMP instruction.
However, this .IF directive results in CMP R0L,#10, and this causes an error. To avoid this,
the program must be written in the following way:
.IF B (#10<LT>R0L)
.ENDI
Structured assembly statements generate symbols in the forms shown below.
.IF
.SWITCH
.FOR[U]
.WHILE
.REPEAT
Accordingly, such symbols are not available to the user.
MOV.W R1,R2
MOV.W R1,R2
Notes on Structured Assembly
_$I00000 to _$I99999
_$S00000 to _$S99999
_$F00000 to _$F99999
_$W00000 to _$W99999
_$R00000 to _$R99999
; Expanded to CMP #10,R0L
; Expanded instruction will cause an error
791