cp3cn17 National Semiconductor Corporation, cp3cn17 Datasheet - Page 170

no-image

cp3cn17

Manufacturer Part Number
cp3cn17
Description
Reprogrammable Connectivity Processor With Can Interface
Manufacturer
National Semiconductor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
cp3cn17K38
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
cp3cn17K38/NOPB
Manufacturer:
Texas Instruments
Quantity:
10 000
www.national.com
23.2.8
The Counter (COUNTx) registers are word-wide read/write
registers. There are a total of four registers called COUNT1
through COUNT4, one for each of the four timer sub-
systems. Software may read the registers at any time.
Reading the register will return the current value of the
counter. The register may only be written if the counter is
stopped (i.e. if both TxRUN bits associated with a timer sub-
system are clear). The registers are cleared at reset.
23.2.9
The PERCAPx registers are word-wide read/write registers.
There are a total of four registers called PERCAP1 through
PERCAP4, one for each timer subsystem. The registers
hold the period compare value in PWM mode of the counter
value at the time the last associated capture event occurred.
In PWM mode the register is double buffered. If a new peri-
od compare value is written while the counter is running, the
write will not take effect until counter value matches the pre-
vious period compare value or until the counter is stopped.
Reading may take place at any time and will return the most
recent value which was written. The PERCAPx registers are
cleared at reset.
15
15
Counter Register n (COUNTx)
Period/Capture Register n (PERCAPx)
PCAPx
CNTx
0
0
170
23.2.10 Duty Cycle/Capture Register n (DTYCAPx)
The Duty Cycle/Capture (DTYCAPx) registers are word-
wide read/write registers. There are a total of four registers
called DTYCAP1 through DTYCAP4, one for each timer
subsystem. The registers hold the period compare value in
PWM mode or the counter value at the time the last associ-
ated capture event occurred. In PWM mode, the register is
double buffered. If a new duty cycle compare value is written
while the counter is running, the write will not take effect un-
til the counter value matches the previous period compare
value or until the counter is stopped. The update takes effect
on period boundaries only. Reading may take place at any
time and will return the most recent value which was written.
The DTYCAPx registers are cleared at reset.
15
DCAPx
0

Related parts for cp3cn17