IDT82P2816BB IDT, Integrated Device Technology Inc, IDT82P2816BB Datasheet - Page 75

no-image

IDT82P2816BB

Manufacturer Part Number
IDT82P2816BB
Description
IC LIU T1/J1/E1 16+1CH 416-PBGA
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT82P2816BB

Function
Line Interface Unit (LIU)
Interface
E1, J1, T1
Number Of Circuits
1
Voltage - Supply
1.8V, 3.3V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
*
Includes
Defect and Alarm Detection, Driver Over-Current Detection and Protection, LLOS Detection, PRBSARB / IB Detection and Generation
Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Current - Supply
-
Power (watts)
-
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
Other names
82P2816BB

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82P2816BB
Manufacturer:
ADI
Quantity:
6 358
Part Number:
IDT82P2816BB
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82P2816BBG
Manufacturer:
IDT Integrated Device Technolo
Quantity:
135
Part Number:
IDT82P2816BBG
Manufacturer:
IDT
Quantity:
70
Part Number:
IDT82P2816BBG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
MON - G.772 Monitor Configuration Register
Address: 0C0H
Type: Read / Write
Default Value: 00H
Programming Information
IDT82P2816
7 - 6
5 - 0
Bit
7
-
MON[5:0]
Name
-
6
-
Reserved.
These bits determine whether the G.772 Monitor is implemented. When the G.772 Monitor is implemented, these bits select one
transmitter or receiver to be monitored by channel 0.
000000: No transmitter or receiver is monitored. (default)
000001: The receiver of channel 1 is monitored.
000010: The receiver of channel 2 is monitored.
......
001111: The receiver of channel 15 is monitored.
010000: The receiver of channel 16 is monitored.
010001 ~ 011111: Reserved.
100000: No transmitter or receiver is monitored.
100001: The transmitter of channel 1 is monitored.
100010: The transmitter of channel 2 is monitored.
......
101111: The transmitter of channel 15 is monitored.
110000: The transmitter of channel 16 is monitored.
110001 ~ 111111: Reserved.
MON5
5
MON4
4
16(+1) CHANNEL HIGH-DENSITY T1/E1/J1 LINE INTERFACE UNIT
75
MON3
3
Description
MON2
2
MON1
1
February 6, 2009
MON0
0

Related parts for IDT82P2816BB