IDT82P2816BB IDT, Integrated Device Technology Inc, IDT82P2816BB Datasheet - Page 46

no-image

IDT82P2816BB

Manufacturer Part Number
IDT82P2816BB
Description
IC LIU T1/J1/E1 16+1CH 416-PBGA
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT82P2816BB

Function
Line Interface Unit (LIU)
Interface
E1, J1, T1
Number Of Circuits
1
Voltage - Supply
1.8V, 3.3V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
*
Includes
Defect and Alarm Detection, Driver Over-Current Detection and Protection, LLOS Detection, PRBSARB / IB Detection and Generation
Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Current - Supply
-
Power (watts)
-
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
Other names
82P2816BB

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82P2816BB
Manufacturer:
ADI
Quantity:
6 358
Part Number:
IDT82P2816BB
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82P2816BBG
Manufacturer:
IDT Integrated Device Technolo
Quantity:
135
Part Number:
IDT82P2816BBG
Manufacturer:
IDT
Quantity:
70
Part Number:
IDT82P2816BBG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Functional Description
IDT82P2816
Figure-26 Automatic Error Counter Updating
No
Data in the Error Counter transfers
Automatic Error Counter Updating
to the ERRCH & ERRCL registers
TMOV_IS is cleared after a '1' is
The Error Counter is cleared
Read the ERRCH & ERRCL
registers in the next second
One second expired?
(TMOV_IS = 1 ?)
(CNT_MD = 1)
written to it
Counting
Yes
same process
in the next
repeat the
second
16(+1) CHANNEL HIGH-DENSITY T1/E1/J1 LINE INTERFACE UNIT
46
3.5.6.2 Manual Error Counter Updating
updated manually.
ERR,...), the Error Counter transfers the accumulated error numbers to
the ERRCH and ERRCL registers and the Error Counter will be cleared
to start a new round counting. The ERRCH and ERRCL registers should
be read in the next round of error counting, otherwise they will be over-
written.
error to be accumulated, the registers will be overflowed. The overflow is
indicated by the CNTOV_IS bit (b0, INTS2,...) and will induce an inter-
rupt reported by INT if not masked by the CNTOV_IM (b0, INTM2,...).
Figure-27.
When the CNT_MD bit (b1, ERR,...) is ‘0’, the Error Counter is
When there is a transition from ‘0’ to ‘1’ on the CNT_STOP bit (b0,
When the ERRCH and ERRCL registers are all ‘1’s and there is still
The process of manual Error Counter updating is illustrated in
Figure-27 Manual Error Counter Updating
No
Data in the Error Counter transfers
to the ERRCH & ERRCL registers
Manual Error Counter Updating
The Error Counter is cleared
Read the ERRCH & ERRCL
registers in the next round
A transition from '0' to
'1' on CNT_STOP ?
(CNT_MD = 0)
Counting
Yes
February 6, 2009
(CNT_STOP
next round)
repeat the
process in
before the
the next
must be
cleared
round
same

Related parts for IDT82P2816BB