DS33R11 Maxim Integrated Products, DS33R11 Datasheet - Page 78

no-image

DS33R11

Manufacturer Part Number
DS33R11
Description
Network Controller & Processor ICs Ethernet Mapper with Integrated T1-E1-J1
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS33R11

Product
Framer
Number Of Transceivers
1
Supply Voltage (max)
1.89 V, 3.465 V
Supply Voltage (min)
1.71 V, 3.135 V
Supply Current (max)
100 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
BGA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS33R11
Manufacturer:
DS
Quantity:
15
Part Number:
DS33R11
Manufacturer:
NSC
Quantity:
2 877
Part Number:
DS33R11
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11+
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+CJ2
Manufacturer:
Maxim Integrated
Quantity:
10 000
10.7 Error Counters
The transceiver contains four counters that are used to accumulate line-coding errors, path errors, and
synchronization errors. Counter update options include one-second boundaries, 42ms (T1 mode only), 62ms (E1
mode only), or manual. See Error-Counter Configuration Register (TR.ERCNT). When updated automatically, the
user can use the interrupt from the timer to determine when to read these registers. All four counters saturate at
their respective maximum counts, and they do not roll over. Note: Only the line-code violation count register has
the potential to overflow, but the bit error would have to exceed 10E-2 before this would occur.
10.7.1 Line-Code Violation Counter (TR.LCVCR)
In T1 mode, code violations are defined as bipolar violations (BPVs) or excessive 0s. If the B8ZS mode is set for
the receive side, then B8ZS codewords are not counted. This counter is always enabled; it is not disabled during
receive loss-of-synchronization (RLOS = 1) conditions.
Table 10-5 T1 Line Code Violation Counting Options
In E1 mode, either bipolar violations or code violations can be counted. Bipolar violations are defined as
consecutive marks of the same polarity. In this mode, if the HDB3 mode is set for the receive side, then HDB3
codewords are not counted as BPVs. If TR.ERCNT.3 is set, then the LVC counts code violations as defined in ITU
O.161. Code violations are defined as consecutive bipolar violations of the same polarity. In most applications, the
framer should be programmed to count BPVs when receiving AMI code and to count CVs when receiving HDB3
code. This counter increments at all times and is not disabled by loss-of-sync conditions. The counter saturates at
65,535 and does not roll over. The bit-error rate on an E1 line would have to be greater than 10
would saturate
Table 10-6. E1 Line-Code Violation Counting Options
COUNT EXCESSIVE
E1 CODE VIOLATION SELECT
(TR.ERCNT.0)
ZEROS?
Yes
Yes
No
No
(TR.ERCNT.3)
(Table
0
1
10-6).
B8ZS ENABLED?
(TR.T1RCR2.5)
Yes
Yes
No
No
COUNTED IN THE LCVCRs
78 of 344
Table 10-5
BPVs
BPVs + 16 consecutive 0s
BPVs (B8ZS codewords not counted)
BPVs + 8 consecutive 0s
BPVs
CVs
COUNTED IN THE LCVCRs
shows what the LCVCRs count.
-2
before the VCR

Related parts for DS33R11