DS33R11 Maxim Integrated Products, DS33R11 Datasheet - Page 64

no-image

DS33R11

Manufacturer Part Number
DS33R11
Description
Network Controller & Processor ICs Ethernet Mapper with Integrated T1-E1-J1
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS33R11

Product
Framer
Number Of Transceivers
1
Supply Voltage (max)
1.89 V, 3.465 V
Supply Voltage (min)
1.71 V, 3.135 V
Supply Current (max)
100 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
BGA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS33R11
Manufacturer:
DS
Quantity:
15
Part Number:
DS33R11
Manufacturer:
NSC
Quantity:
2 877
Part Number:
DS33R11
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11+
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+CJ2
Manufacturer:
Maxim Integrated
Quantity:
10 000
DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver
9.16.2 Repetitive Pattern Synchronization
Repetitive pattern synchronization synchronizes the receive pattern generator to the incoming repetitive pattern.
The receive pattern generator is synchronized by searching each incoming data stream bit position for the
repetitive pattern, and then checking the next 32 data stream bits. Synchronization is achieved if all 32 bits match
the incoming pattern. If at least sis incoming bits in the current 64-bit window do not match the receive PRBS
pattern generator, automatic pattern resynchronization is initiated. Automatic pattern resynchronization can be
disabled.
Figure 9-10. Repetitive Pattern Synchronization State Diagram
Sync
1 bit error
Verify
Match
Pattern Matches
9.16.3 Pattern Monitoring
Pattern monitoring monitors the incoming data stream for Out Of Synchronization (OOS) condition, bit errors, and
counts the incoming bits. An OOS condition is declared when the synchronization state machine is not in the
“Sync” state. An OOS condition is terminated when the synchronization state machine is in the “Sync” state.
Bit errors are determined by comparing the incoming data stream bit to the receive pattern generator output. If they
do not match, a bit error is declared, and the bit error and bit counts are incremented. If they match, only the bit
count is incremented. The bit count and bit error count are not incremented when an OOS condition exists.
9.16.4 Pattern Generation
Pattern Generation generates the outgoing test pattern, and passes it onto Error Insertion. The transmit pattern
generator is a 32-bit shift register that shifts data from the least significant bit (LSB) or bit 1 to the most significant
n
y
bit (MSB) or bit 32. The input to bit 1 is the feedback. For a PRBS pattern (generating polynomial x
+ x
+ 1), the
feedback is an XOR of bit n and bit y. For a repetitive pattern (length n), the feedback is bit n. The values for n and
y are individually programmable. The output of the receive pattern generator is the feedback. If QRSS is enabled,
the feedback is an XOR of bits 17 and 20, and the output is forced to one if the next 14 bits are all zeros. QRSS is
programmable (on or off). For PRBS and QRSS patterns, the feedback is forced to one if bits 1 through 31 are all
zeros. When a new pattern is loaded, the pattern generator is loaded with a pattern value before pattern generation
n
starts. The pattern value is programmable (0 – 2
- 1). When PRBS and QRSS patterns are generated the seed
value is all ones.
64 of 344