DS33R11 Maxim Integrated Products, DS33R11 Datasheet - Page 76

no-image

DS33R11

Manufacturer Part Number
DS33R11
Description
Network Controller & Processor ICs Ethernet Mapper with Integrated T1-E1-J1
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS33R11

Product
Framer
Number Of Transceivers
1
Supply Voltage (max)
1.89 V, 3.465 V
Supply Voltage (min)
1.71 V, 3.135 V
Supply Current (max)
100 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
BGA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS33R11
Manufacturer:
DS
Quantity:
15
Part Number:
DS33R11
Manufacturer:
NSC
Quantity:
2 877
Part Number:
DS33R11
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS33R11+
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS33R11+CJ2
Manufacturer:
Maxim Integrated
Quantity:
10 000
10.5 E1 Framer/Formatter Control and Status
The E1 framer portion of the transceiver is configured by a set of four control registers. Typically, the control
registers are only accessed when the system is first powered up. Once the device has been initialized, the control
registers need only to be accessed when there is a change in the system configuration. There are two receive
control registers (TR.E1RCR1 and TR.E1RCR2) and two transmit control registers (TR.E1TCR1 and TR.E1TCR2).
There are also four status and information registers. Each of these eight registers is described in this section.
Table 10-3. E1 Sync/Resync Criteria
MULTIFRAME
FRAME OR
LEVEL
CRC4
CAS
FAS
FAS present in frame N and
N + 2; FAS not present in
frame N + 1
Two valid MF alignment
words found within 8ms
Valid MF alignment word
found and previous time slot
16 contains code other than
all 0s
SYNC CRITERIA
DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver
76 of 344
Three consecutive incorrect
FAS received
Alternate: (TR.E1RCR1.2 = 1)
The above criteria is met or
three consecutive incorrect bit
2 of non-FAS received
915 or more CRC4 codewords
out of 1000 received in error
Two consecutive MF alignment
words received in error
RESYNC CRITERIA
4.2 and 4.3.2
ITU SPEC.
G.706
G.706
G.732
4.1.1
4.1.2
5.2