EQ-SFM-MAX-V1.3 Equinox Technologies, EQ-SFM-MAX-V1.3 Datasheet - Page 54

MODULE FOR PPM3-MK2 I/O DRIVER

EQ-SFM-MAX-V1.3

Manufacturer Part Number
EQ-SFM-MAX-V1.3
Description
MODULE FOR PPM3-MK2 I/O DRIVER
Manufacturer
Equinox Technologies
Datasheet

Specifications of EQ-SFM-MAX-V1.3

Accessory Type
I/O Driver Module
For Use With/related Products
PPM3-MK2
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
483-1013
2.8 Standalone Remote I/O Programmer Control
2.8.1 Overview
The PPM3 programmer can be controlled using a simple 4-wire Remote I/O (TTL) signalling protocol
as shown in the diagram below. This control method is ideal for interfacing the programmer to In-
Circuit Testers (ICT’s) or other production equipment which does not have an RS-232 port.
Fig. 2.8.1 Remote System Control of Programmer
START
Equinox
ACTIVE
Remote
PPM3
System
Programming
Module
OK
FAIL
GROUND
The Remote System simply asserts the programmer <START> signal to initiate the execution of a
‘Programming Project’. The programmer will then assert the <ACTIVE> signal to indicate that it has
commenced programming. At the end of the Programming operation the programmer asserts either
the <OK> or <FAIL> signal depending on the outcome. The Remote System must then de-assert the
<Start> signal to allow the programmer to reset ready to program the next device.
Please refer to section 2.8.3 for an example of the Remote I/O control signal waveforms for a typical
programming iteration.
th
PPM3 MKII Programmer - User Guide - V1.04 - 10
May 2008
43