AT32UC3L064-D3HES ATMEL [ATMEL Corporation], AT32UC3L064-D3HES Datasheet - Page 650

no-image

AT32UC3L064-D3HES

Manufacturer Part Number
AT32UC3L064-D3HES
Description
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet
27.9.12
Name:
Access Type:
Offset:
Reset Value:
• FLEN: Filter Length
• HYS: Hysteresis Value
• EVENN: Event Enable Negative
• EVENP: Event Enable Positive
• INSELP: Positive Input Select
• INSELN: Negative Input Select
• MODE: Mode
32099D–06/2010
31
23
15
7
-
-
-
-
000: Filter off.
n: Number of samples to be averaged =2
0000: No hysteresis.
1111: Max hysteresis.
0: Do not output event when ACOUT is zero.
1: Output event when ACOUT is zero.
0: Do not output event when ACOUT is one.
1: Output event when ACOUT is one.
00: ACPn pin selected.
01: Reserved.
10: Reserved.
11: Reserved.
00: ACNn pin selected.
01: ACREFN pin selected.
10: Reserved.
11: Reserved.
00: Off.
01: Continuous Measurement Mode.
10: User Triggered Single Measurement Mode.
11: Event Triggered Single Measurement Mode.
AC Configuration Register
30
22
14
6
-
-
-
CONFn
Read/Write
0xD0,0xD4,0xD8,0xDC,0xE0,0xE4,0xE8,0xEC
0x00000000
FLEN
29
21
13
5
-
-
MODE
n
.
28
20
12
4
-
-
27
19
11
3
-
-
INSELP
26
18
10
2
-
-
AT32UC3L016/32/64
HYS
EVENP
25
17
9
1
INSELN
IS
EVENN
24
16
8
0
650